FIS
LISBOA INFORMATIONUse the sector frequency from current AIP and chart
VFR Guide Europe
At a glance
Use the sector frequency from current AIP and chart
For aerodromes without their own published frequency
Normally file at least 30 minutes before departure
Outside controlled airspace within SSR coverage
Licence, medical and 600 kg status with ANAC before entry
Schengen, non-Schengen and permitted airfields.
Read more →Duty, task, activation and closure.
Read more →Lisboa Information and sectoral frequencies.
Read more →122.505 MHz in places without their own frequency.
Read more →Categories G and C, CTR/TMA, ATZ, FIZ and RMZ.
Read more →VMC minima and minimum flight altitudes.
Read more →TA, QNH and cruising levels.
Read more →SEP conditions; UL without night VFR.
Read more →VFR code, mode S/A+C, 8,33 kHz and language.
Read more →License, Medical, Aircraft and 600-kg Question.
Read more →PPR, border status, UL runways and local procedures.
Read more →VFR tunnels and temporary regulations.
Read more →AIP SUP, NOTAM and military activations.
Read more →IPMA briefing and regional specificities.
Read more →Shipboard documents and insurance cover.
Read more →PORTUGAL - the most important points before take-off Cross-border VFR flight: flight plan required; Check in at least 30 minutes before departure.
Mainland airspace: outside CTR/TMA generally G to FL095, above C; controlled airspace only with clearance.
Radio: 8.33 kHz for the relevant controlled airspaces as well as ATZ/FIZ/RMZ.
Transponder: VFR code 7000 outside controlled airspace, provided transponder is present and SSR coverage exists.
Night VFR: generally permitted for appropriately qualified SEPs, with additional national conditions.
UL: Portuguese national law; Foreign UL pilot licenses are not automatically recognized.
Practical value topic
FIS LISBOA INFORMATION - sector-dependent frequencies
SAFETYCOM 122.505 MHz in locations without their own published frequency
VFR code 7000 outside controlled airspace
FPL lead time is generally at least 30 minutes
UL Clarify license/validation issue with ANAC in writing before entry
For flights within the EU/EEA/Switzerland, as long as there is also Schengen traffic, the Portuguese AIP generally does not provide for a separate entry permit under aviation law for normal private travel.
For flights to or from non-Schengen states or third countries, additional PSP, customs and, if necessary, ANAC procedures may be required. This applies in particular to flights to/from Ireland or Cyprus as well as to traffic outside the EU/EEA/Switzerland.
For non-Schengen or third-country flights, check before departure which specific Portuguese airport is allowed to offer border and customs clearance for the planned flight.
Airport of Entry / General Declaration A general obligation to land at a specific Portuguese airport of entry first for a normal Schengen intra-EU private flight does not arise from the current GEN 1.2 rule.
There is no documented general general declaration requirement as a permanent rule for normal private Schengen intra-EU VFR flights. The following applies to different entry profiles: I have no reliable information about this. The specific procedure must be clarified with the destination airport and, if necessary, PSP/Customs.
When is a VFR flight plan required? • for cross-border VFR flights to or from Portugal; • for VFR flights in the controlled airspace of Lisboa and Santa Maria FIR; • at night VFR, as soon as the area surrounding the aerodrome is left; • for certain FIZ, ATZ, RMZ and local procedures. When crossing borders, the route/border point and EET information provided for in AIP must be taken into account in the flight plan.
The flight plan must generally be submitted at least 30 minutes before departure.
The preferred method is the electronic FPL and briefing from NAV Portugal. Alternatively, ARO Portugal can be used.
AFIL For a flight plan posted in the air, NAV Portugal publishes the general purpose frequency 132.075 MHz within the Lisboa FIR.
For VFR flights, the corresponding DEP message is generated by the Flight Data Service after takeoff.
Delay If there is a delay of 30 minutes via EOBT, a DLA report is required; otherwise the flight plan must be canceled or resubmitted.
After landing without ATS If there is no ATS office at the destination airport, the pilot must report the arrival as soon as possible - for example by radio to the ATS office last contacted, electronically via FPL and Briefing or via ARO Portugal.
At an uncontrolled destination airport, never assume without checking that the flight plan has been automatically closed. An open flight plan can trigger unnecessary alerting and SAR measures.
LISBOA INFORMATION is generally responsible on the Portuguese mainland. Radio languages are English and Portuguese.
Frequency/Channel Note
123.755 MHz published FIS range; sector/altitude dependent
130.905 MHz published Lisboa Information Frequency; sector dependent
131.055 MHz published Lisbon Information Frequency; sector dependent
121,500 MHz emergency frequency The frequencies are divided spatially and in height. Always use the latest VFR chart and ENR 2.1/2.1.3 for the specific flight; not treat any single frequency as a nationwide FIS frequency.
SAFETYCOM 122.505 MHz Portugal uses SAFETYCOM at airfields, heliports and UL runways without their own published VHF frequency.
Use is recommended but not generally required as an ATS service. If your own place frequency is published, this remains decisive.
For blind reports, identification, position, altitude, course and intention must be stated; On approach, use is typically recommended within approximately 10 NM or below 2,000 ft AGL.
In Portugal, ICAO classes C, D and G are used for VFR.
Height/Area Class/Importance
Mainland outside CTR/TMA: GND-FL095 G - uncontrolled airspace
Mainland outside CTR/TMA: FL095-FL660 C - controlled airspace
Parts of the high seas within Lisboa FIR Class C partly from FL055 Porto, Lisboa, Faro and Madeira have controlled TMA structures. CTR, FIZ, ATZ, RMZ, TMZ as well as military restricted/danger areas can be found on the current map and ENR 2/ENR 5.
VFR above FL195 For planned VFR flights between FL195 and FL285, the AIP requires special requirements or prior approval. For normal cruise VFR, FL195 is therefore effectively the regular upper limit; Special flights must be clarified in advance in writing with ANAC/ATS.
The basis is SERA and the nationally published Portuguese supplements.
Special VFR Special VFR within a CTR can be approved by ATC. The Portuguese eVFR specifies a ground visibility of at least 1,500 m; The release remains dependent on the traffic situation and other conditions.
VFR on top / above clouds An independent general Portuguese VFR on top permit is not documented as an additional national permanent rule. SERA-VMC, airspace, altitude and clearance conditions remain relevant.
Portugal does not have a uniform nationwide transition altitude. The TA depends on the airport.
Airport/Transition Altitude area
Lisbon 4,000 ft
Airport/Transition Altitude area
Postage 4,000 ft
Faro 4,000ft
Cascais 4,000 ft
Madeira 5,000ft
Porto Santo 5,000 ft
Vila Real 8,000 ft
Bragança 8,000 ft The transition level is QNH dependent.
VFR semicircle rule • Magnetic heading 090°-269°: odd VFR flight levels, e.g. B. FL35, FL55, FL75, FL95. • Magnetic heading 270°-089°: straight VFR flight levels, e.g. B. FL45, FL65, FL85, FL105.
Night VFR is generally permitted in Portugal if the pilot and aircraft meet the relevant requirements. The Portuguese VFR night period is published as Sunset +25 minutes to Sunrise -25 minutes.
UL: no night VFR The current Portuguese eVFR basically only provides for daytime VFR in VMC for UL.
For a transponder-equipped VFR aircraft outside controlled airspace and within SSR coverage, VFR code 7000 applies.
situation code
VFR outside controlled airspace 7000
Entering FIR without previously assigned SSR code 2000 until ATS assigns other code
Unlawful interference 7500
Communication failure 7600
Emergency 7700
An additional blanket Portuguese Mode S requirement for all VFR flights cannot be derived from the AIP bodies evaluated. I don't have any reliable information about this. Specific TMZ and the applicable European equipment regulations remain to be observed.
In the Lisboa FIR, aircraft in particular in Class C, Class D, ATZ, FIZ and RMZ must be equipped with a 8,33-kHz-capable radio, as far as radio traffic is required.
VFR flights in Class G which use FIS also require 8,33-kHz radio technology suitable for the corresponding two-way communication.
For the Santa Maria FIR, 8,33-kHz equipment is not generally required to the same extent according to the published NAT rule; However, the required two-way communication with the responsible ground site remains.
Principle Portugal treats UL nationally. UL rules must therefore not be automatically derived from EASA/SEP rules.
ANAC currently answers the question of whether UL flying in Portugal is allowed with a UL license of another nationality with an express no. UL licensing is national law; The rights of a foreign UL license therefore do not automatically apply in Portugal.
Portuguese law fundamentally opens up validation options under certain reciprocity/recognition conditions. A current, generally applicable list of corresponding agreements for all European UL licenses is not clearly documented.
Practical consequence Before flying in as pilot-in-command of a foreign UL, the recognition/validation of the specific pilot authorization should be clarified in writing with ANAC.
Simply holding a PPL(A) or LAPL(A) license does not automatically result in Portuguese UL rights. For this purpose, ANAC requires the requirements provided for by national UL law.
ANAC publishes that a non-Portuguese Medical will not be automatically accepted for the Portuguese UL licensing system. This is to be distinguished from the EASA recognition of a Part-MED-Medical for SEP/PPL/LAPL.
Category published by ANAC
Land plane 450 kg
Land aircraft with ballistic rescue system 472.5 kg
Seaplane / Amphibium 495 kg A general Portuguese 600-kg -UL class or automatic recognition of all UL approved abroad with 600 kg is not documented in the evaluated current ANAC publications. I do not have any reliable information on this.
600-kg -UL Obtain written ANAC confirmation from a foreign registered 600-kg -UL before the flight, indicating type, registration, MTOM, registration document and national category.
UL runways can be used for certain intra-EU/Schengen flights provided the other operational requirements are met. However, they are not automatically suitable as border crossing points for flights that require border clearance.
For non-Schengen traffic, a suitable airport must be chosen that accepts UL and enables the necessary border/customs procedures.
The current AD/VFR AD page must be checked before each flight.
Coordinated airports Lisboa, Porto, Madeira and, seasonally, Faro should be taken into account as coordinated or slot-relevant airports. For GA, the current slot/handling situation must be checked before the flight.
In the Lisboa area there are published VFR tunnels to route VFR traffic through or around the heavily used terminal area.
Temporary Restrictions - Stand 23.08.2026 AIP SUP 033/2026 releases the closure of the VFR Route TUNNEL NORTHWEST (TNW) expected until 31.12.2026. AIP SUP 064/2026 contains further temporary VFR controls in the Lisboa TMA area. This information is not a permanent rule; Check current SUP and NOTAM before each flight.
AIP SUP 010/2026 publishes extensive areas for state UAS surveillance and reconnaissance flights within the Lisboa FIR for 2026. Several regions of the mainland are affected.
For VFR flights over inland Portugal, check AIP SUP, AUP/current airspace activity and NOTAM particularly carefully.
AIP ENR 5.6 identifies bird concentration areas in the greater Tejo / Lisboa-Montijo area. The published height and avoidance information must be observed for the mapped areas.
The main period of higher bird abundance is approximately from October 1st to the end of February. The current ENR-5 chart should be given special consideration for low-altitude/VFR routes in wetland and Tagus areas.
The responsible meteorological service is IPMA - Instituto Português do Mar e da Atmosfera.
VOLMET frequency
Lisboa VOLMET 126.405 MHz
Santa Maria VOLMET 124.850 MHz
For a normal EU-registered private SEP flight, the aircraft, pilot, radio and insurance documents required by EU/EASA law must be valid.
MTOM minimum third party liability coverage
under 500 kg 0.75 million SDR
500 to less than 1,000 kg 1.5 million SDR
1,000 to less than 2,700 kg 3 million SDR
For foreign UL, aircraft/flight authorization documents from the country of origin, suitable pilot qualifications and insurance valid in Portugal are particularly relevant.
Due to national license and weight issues, the complete documentation of a foreign UL should be agreed in writing with ANAC before departure.
A concrete line-by-line check of an older Portugal edition was not possible because the old template provided deals with Denmark. However, the following general statements in particular should be avoided for a current Portugal guide:
Current official Portuguese and European sources were primarily used for the country overview. For real flight preparation, the version valid at the time of the flight is relevant. • NAV Portugal - Aeronautical Information Service / eAIP • NAV Portugal - FPL and Briefing • NAV Portugal eVFR - ENR 1.2 Visual Flight Rules • NAV Portugal - ENR 1.4 Airspace Classification • NAV Portugal - ENR 1.6 SSR/Transponder Procedures • NAV Portugal - ENR 1.7 Altimeter Setting / Cruising Levels • NAV Portugal - ENR 1.10 Flight Planning • NAV Portugal - ENR 2.1 Lisboa FIR / FIS / Airspace • ANAC Portugal - Ultraleves and Pilot FAQ • IPMA - Aviation Weather Self-Briefing • EUR-Lex - Regulation (EC) No. 785/2004 Aviation Insurance
This overview is intended for flight preparation, but does not replace current AIP/eVFR, AIP SUP, NOTAM, weather briefing, current airport information and required official approvals.
For foreign UL - in particular in the case of a foreign UL pilot license or an aircraft registered as UL above the national weight limits published by ANAC - Portugal should not be scheduled as an automatically permitted entry country without prior written clarification with ANAC.
Official direct links
The AIP, supplements, NOTAM, weather and aerodrome data valid on the day of flight remain authoritative. Links open the respective official source in a new window.
This country guide supports individual flight preparation. It does not replace the AIP, AIP SUP, NOTAM, AUP/UUP, weather and aerodrome information valid on the day of flight.
Systematic reproduction, compilation or redistribution of the complete VFR Guide Europe is prohibited.