FIS
Kaunas Information124.530 / 124.605 MHz · Palanga 125.730 · Vilnius 123.855
VFR Guide Europe
At a glance
124.530 / 124.605 MHz · Palanga 125.730 · Vilnius 123.855
Nationwide
Except in specifically suitable airspace
Plan for altitude-reporting A/C or Mode S
Recheck Belarus/Russia border, ADIZ and security information
Schengen and external borders with Belarus and Russia.
Read more →Duty, task, activation and closure.
Read more →Kaunas, Palanga and Vilnius Information.
Read more →Controlled areas, TMZ and border regions.
Read more →VMC minima, minimum heights and FL195.
Read more →Transition Altitude, QNH and cruising altitudes.
Read more →Requirements and special features at night.
Read more →TMZ, Mode S or A/C and 8,33 kHz.
Read more →National requirements for ultralight aircraft.
Read more →PPR, operating hours and local procedures.
Read more →Bird migration and sensitive areas.
Read more →Official weather information and briefing.
Read more →GNSS incidents and operational information.
Read more →The operational information was compiled using up-to-date official Lithuanian and European sources. Checked publication status: Main AIP AIRAC AMDT 003/2026, effective since 11.06.2026; AIP VFR AMDT 80/26, also effective since 11.06.2026. The AIP-VFR supplement page does not show any VFR supplements at the research status. General AIP SUP and NOTAM must nevertheless be checked route-related. Official source: Oro navigacija / AIS Lithuania - AIP, AIP VFR and Supplements
Lithuania is an EU and Schengen state. In principle, a Lithuanian entry permit is not required for a private, non-commercial flight with a foreign civil aircraft. Liability insurance is required. Official source: AIP Lithuania GEN 1.2 - Entry, Transit and Departure of Aircraft
For flights between Lithuania and other Schengen countries, the obligation to use an airfield with border, customs and other control points does not apply in principle. This applies as long as Lithuania does not reintroduce temporary controls at the Schengen internal borders. In the case of the actual border crossing, a distinction must be made:
Thus, for example, a VFR entry from Poland or Latvia in uncontrolled airspace is not limited to individual border crossing points. Official source: AIP Lithuania GEN 1.2
For international arrivals or departures where border, customs or other controls are required, an aerodrome shall be used where the appropriate controls can be carried out. Particular caution is required on the borders with Belarus and Russia/Kaliningrad. In uncontrolled airspace, the border may only be crossed via published entry/exit/intermediate points. In addition, there is a 4-NM border area along the border with non-EU countries. For flights within this border area, the AIP basically requires:
For international flights that actually cross the border with a non-Schengen state, the AIP contains an exception to the military permit requirement mentioned therein; the remaining border and ATS procedures remain in place. Official source: AIP Lithuania GEN 1.2
GEN 1.2 contains General Declaration and, where applicable, Passenger and Cargo Manifesto for flights actually subject to border/customs/health clearance. Without passengers or cargo, only the General Declaration remains for this clearance. For the normal private intra-Schengen flight, there is no general obligation to routinely file a General Declaration. Official source: AIP Lithuania GEN 1.2
Private, non-commercial SEP flights do not require a general national entry permit. The usual European aircraft, license, medical and insurance requirements remain unaffected.
The general AIP rule “no entry permit for foreign non-commercial civil aircraft” is also relevant for the flight operation. However, it does not automatically answer the question of recognition of a foreign national UL pilot license. Therefore, see separate chapter UL special schemes.
Compared to many other European countries, Lithuania has a relatively far-reaching schedule regime. According to ENR 1.10, an FPL is intended in particular for:
For a pure flight within a published ATZ, ENR 1.10 does not require a flight plan. Official source: AIP Lithuania ENR 1.10 - Flight Planning
For a typical Germany-Poland-Lithuania flight, an FPL is required for international entry into Lithuania at the latest. In addition, the Lithuanian AIP explicitly lists flights in uncontrolled airspace as FPL cases. One should therefore not assume the usual assumption in some other states that a pure Class-G flight without an FPL is easily possible.
Official source: AIP Lithuania ENR 1.10
VFR flight plans can be submitted via Vilnius ARO, self-briefing or online via Oro navigacija. Vilnius ARO / Briefing
H2 4
phone
+370 706 94 694
Additional current briefing number
+370 610 25 217
briefing@ans.lt
IMPORTANT After submitting the flight plan, the AIP expressly requires a call to Vilnius ARO to confirm that the FPL has actually been received. Oro navigacija – Flight Plan. Official source: AIP Lithuania ENR 1.10
In the case of a controlled VFR flight, in the event of a delay of more than 30 minutes compared to EOBT the FPL must be changed or changed. be renounced. In the case of an uncontrolled flight, this threshold is 1 hour. Changes and cancellations must be notified to ATS. Official source: AIP Lithuania ENR 1.10
The current sections ENR 1.10 and the AIP VFR examined do not describe an independent, generally applicable pilot-by-phone procedure, as is known from individual other states. For the specific question whether a pilot DEP/activation message is additionally required for a take-off from an unmanned aerodrome or operating site:
Before such a departure, the procedure should therefore be clarified with Vilnius ARO.
After the landing, an Arrival Report must generally be done immediately. When landing at an aerodrome with ATS, an additional arrival message is not required unless explicitly requested by ATS. When landing without ATS, the flight plan shall be closed as soon as possible on the fastest available route at Vilnius ARO:
Vilnius ARO + 370 706 94 694
SEARCH AND RESCUE If 30 does not receive a flight plan closure message minutes after the expected completion, a search and rescue operation shall be initiated after the Lithuanian AIP.
Closing an FPL should therefore be one of the first actions immediately after landing. Official source: AIP Lithuania ENR 1.10
FIS for uncontrolled airspace is generally offered H2 4; Operating languages are Lithuanian and English. Official source: AIP Lithuania ENR 2.1
Area / Callsign
Channel
KAUNAS INFORMATION
124.530 / 124.605
Palanga Information
125.730
VILNIUS INFORMATION
123.855
Emergency
121.500
The duplicate entry for KAUNAS INFORMATION is not a clerical error: The current ENR 2.1 releases two Kaunas sector configurations with different lateral boundaries and different ATS locations - once 124.530, once 124.605. Therefore, one of the two channels may not be stored across the board for all Kaunas FIS; The current VFR map, sector boundary and, if applicable, NOTAM are relevant.
In an older 2025 he AIP version was still listed a separate ŠIAULIAI INFORMATION 124.455 sector. In the current ENR 2.1 of the 11.06.2026, this no longer appears as a separate FIS sector.
I could not verify a special air-to-air channel for motor flight/UL, which could be reliably adopted from the current official AIP.
In the Vilnius FIR, the classes C, D and G are essentially used for the VFR operation relevant here. Classes A, B, E and F are not used in the Vilnius FIR. Typical structure:
Individual controlled airspace may become Class G in accordance with AIP when ATS is not operated. Therefore, the operating times of the respective structure must be checked. Official source: AIP Lithuania ENR 1.2 and ENR 2.1
Lithuania has numerous EYP-Prohibited Areas, EYR-Restricted Areas, Danger Areas, TSA as well as militarily used and flexibly activated areas. A significant portion of military restricted areas will be activated through Airspace Management; Activations can be announced via NOTAM and AUP/UUP. Appropriate military approval is generally required for entry into Prohibited or Restricted Areas.
PRACTICAL NOTE For VFR flights through Lithuania, a static chart alone is insufficient. AUP/UUP and current NOTAM are mandatory parts of the route check. Official source: AIP Lithuania ENR 5.1
Lithuania applies the European SERA rules. Official source: AIP Lithuania ENR 1.2 / SERA
Height
airspace
Flight visibility
Cloud separation
from FL100
C/D/G
8 km
1.500 m horizontally / 1.000 ft vertically
under FL100, above 3.000 ft
C/D/G
5 km
1.500 m / 1.000 ft
to 3.000 ft
C/D
5 km
1.500 m / 1.000 ft
to 3.000 ft
Basically 5 km
clear of cloud / surface in sight
Under special conditions approved by the Transport Competence Agency, reduced flight visibility is possible; This is not a general clearance for normal cruise flights.
Except for take-off/landing or with special permission:
Official source: AIP Lithuania GEN 1.7 / SERA
SVFR is possible within a CTR with ATC clearance. For aeroplanes, in particular:
Official source: AIP Lithuania GEN 1.7 / SERA
According to SERA, VFR flights above FL195 are generally not permitted. Exceptions are only possible in airspace reserved for this purpose or with special ATS authorisation up to and including FL285. For normal SEP/UL cruises, therefore, FL195 is the practical upper VFR limit. Official source: SERA. 5005
A separate Lithuanian ‘VFR-on-top’ procedure is not published in the AIP sections examined. Above the low Class-G layer, the normal SERA-VMC distances apply; in Class G in the lower layer, on the other hand, earth vision is expressly prescribed. Official source: AIP Lithuania ENR 1.2 / SERA
The transition altitude is in the entire Vilnius FIR 5.000 ft MSL. The Transition Level at international airports is usually broadcast via ATIS or communicated by ATC.
SPECIFIC FL095 shall not be used for VFR flights in uncontrolled Class G airspace. Official source: AIP Lithuania ENR 1.7
Magnetic track
VFR level
000°-179°
FL035, 055, 075, 095...
180°-359°
FL045, 065, 085, 105...
In addition, the usable height depends on airspace sub-limits and terrain.
Night VFR is basically possible in Lithuania. For night VFRs, in particular:
Official source: AIP Lithuania GEN 1.7 / SERA Night VFR
For SEP, the EASA license requirements also apply. For the exercise of PPL/LAPL privileges under VFR at night, the corresponding night rating/night rating shall be under FCL. 810 is required. The equipment shall comply with applicable Part-NCO requirements, including night lighting and additional flight and navigation instrumentation. Official source: Part-FCL FCL. 810 and Part-NCO
Whether and under what conditions a foreign-licensed UL with a foreign national UL license may carry out night VFR in Lithuania could not be clearly deduced from a currently applicable official Lithuanian regulation.
Before a UL night flight, a written clarification with TKA/LTSA is required.
Virtually all of Lithuania’s controlled and uncontrolled airspace is designated as the Transponder Mandatory Zone (TMZ). Excluded are designated ATCs and special categories explicitly mentioned.
Generally required:
The exceptions specifically mentioned concern, inter alia, flights exclusively within certain ATZs, sailplanes, motorised hang gliders, free balloons and simple aircraft. For certain exempt categories, an electronic identification solution recognised by Oro navigacija may alternatively be used in uncontrolled airspace. This shall not be considered a replacement in controlled airspace. Otherwise, an aircraft without an A+C/S shall only be operated with an appropriate approval from the ATS provider. Official source: AIP Lithuania GEN 1.2 and GEN 1.5
The AIP does not mention “ultra-light aircraft” as a general transponder exception. Therefore, a foreign three-axle vehicle should under no circumstances assume that it is permitted to fly without a transponder solely on the basis of its UL approval. Whether a specific UL falls within the Lithuanian legal definition of a “simple aircraft”:
For a normal 472,5 -/ 600-kg triaxle, the safe practical planning is therefore: 8,33-kHz -radio + mode S or provide at least Mode A+C, as long as no written exception has been confirmed.
The current main AIP ENR 1.6 publishes the international emergency codes 7500 / 7600 / 7700 and ATC-assigned codes. A single, unambiguously identifiable code as a universal Lithuanian VFR standard code, I could not reliably verify in the current main AIP.
Therefore use the code assigned by ATS or, before an uncontrolled flight, check the current VFR chart and AIP status. Official source: AIP Lithuania ENR 1.6
For IFR and VFR flights within the Vilnius FIR/UIR, 8,33-kHz-capable VHF radio is required. In the flight plan, item 10 shall be marked with Y if appropriately equipped. The operating languages vis-à-vis ATC/FIS are English and Lithuanian. For a foreign pilot, English is therefore provided regularly. RMZ procedures follow SERA: On the published channel, listening shall be maintained and the required initial message dispatched before arrival. Official source: AIP Lithuania GEN 1.2, GEN 1.5 / SERA. 6005
This section must be handled with particular care because UL is regulated nationally in Lithuania and an EASA SEP rule cannot be automatically transferred to UL.
The AIP GEN 1.2 does not require a general flight permit for non-commercial flights of foreign civil aircraft.
In addition, the LTSA Regulation 2 BE- 252, applicable since 01.05.2025, provides for foreign aircraft of the Experimental Category, registered in an ICAO State, that they may be operated in Lithuania if:
From this provision, it cannot be safely concluded solely on the basis of an MTOM of 472,5 kg or 600 kg that any German or other foreign UL can be automatically assigned to the Lithuanian “Experimental Category” and thus operated without further recognition.
For a specific UL, it should therefore be clarified in writing to TKA/LTSA which Lithuanian category it is assigned with registration, type, MTOM and airworthiness document before the first trip to Lithuania. Official source: AIP Lithuania GEN 1.2 LTSA Director Order 2 BE-252
Lithuania has national arrangements for aircraft not fully regulated by EASA. A general official rule “all foreign 600-kg -UL are automatically recognized” could not be verified.
The MTOM alone is therefore not sufficient proof of an entry permit or recognition.
There is a particularly important legal situation here at the time of research: Lithuanian Aviation Law was amended by Law XV- 567; However, new provisions on UL/national licensing material only enter into force at the 31.12.2026. They may not yet be used as applicable law for a flight in August 2026. The currently consolidated version for 01.06.- 30.12.2026 confirms this transitional status. A publicly available regulation in force today, at the 23.08.2026, which clearly confirms an automatic short-term recognition of a foreign UL pilot licence, could not be robustly established.
Before a flight, a written confirmation from TKA/LTSA is therefore required to recognize the specific foreign license. Official source: Lithuanian Aviation Law, consolidated version 01.06.- 30.12.2026; Amendment Law XV-567
Since the current recognition of the foreign UL pilot licence could not be clearly proven, the automatic recognition of the respective national UL medical cannot be confirmed with certainty.
A civil liability insurance of the aircraft operator is required according to GEN 1.2. A proof of insurance should be carried on board. Official source: AIP Lithuania GEN 1.2
There is no blanket exception for UL:
Official source: AIP Lithuania GEN 1.5
Here, on the other hand, there is an expressly published special feature: GEN 1.5 exempts ultra-light aircraft from the general obligation there to carry an ELT on 121,5 MHz and 406 MHz. This exception concerns only this specific AIP-ELT rule and cannot be interpreted as a blanket exemption from other possibly applicable equipment rules. Official source: AIP Lithuania GEN 1.5
No SEP night flight rule automatically transferred to UL.
Before the first Lithuanian flight, have it confirmed in writing:
Conditions vary considerably between international commercial airports and smaller airports. Therefore, PPR, operating hours, UL approval, customs, handling or parking facilities may not be derived from a general country rule. Before each flight, the AD section or Check current VFR airfield map and NOTAM. For example, Vilnius International: For incoming General Aviation flights, PPR is provided in principle; Ground handling must be coordinated before the PPR registration, and PPR coordination is generally carried out at least 24 hours before. For VFR flights in Vilnius TMA/CTR, the current AD page also requires FPL, ATC-Clearance at the latest 5 minutes before arrival and continuous two-way radio. Similar VFR methods also exist in Palanga, for example. UL: Whether a particular aerodrome accepts foreign UL must be based on its current AD/VFR publication. be checked directly with the operator. A nationwide release of all airfields for foreign UL could not be verified. Official source: AIP Lithuania AD 2 EYVI and EYPA
In ENR 5.6, Lithuania explicitly refers to significant migratory activity, especially on the Baltic Sea coast and the Curonian port. Particularly intense periods are:
A significant proportion of migration occurs at night and can reach altitudes of several thousand metres. Official source: AIP Lithuania ENR 5.6
NATIONAL SPECIFICITY In the published ornithological protected areas, motor-powered aircraft are in principle prohibited from flying below 1 km altitude; Excluded are certain governmental, SAR and emergency operations.
The protected areas are mapped in ENR 6.10. For VFR flights, this national 1-km rule is much stricter than the normal SERA minimum flight altitude and therefore must be taken into account in the route planning. Official source: AIP Lithuania ENR 5.6 / ENR 6.10
The official meteorological service for civil aviation is the Lithuanian Hydrometeorological Service (LHMS). Aviation Forecast / Briefing: +370 648 05 448 and +370 648 06 768. The service provides METAR, TAF, SIGMET, AIRMET, low-level forecasts and consultation. For non-scheduled flights within Europe, GEN 3.5 specifies advance notice of generally 3 hours for specially requested consultation or flight documentation. LHMS Aviation Weather. Official source: AIP Lithuania GEN 3.5
The most important special feature for foreign VFR pilots is the very extensive transponder and radio obligation also in Class-G airspace. “Staying under controlled airspace and flying on without a transponder” is basically not a robust strategy in Lithuania. Official source: AIP Lithuania GEN 1.2
The 4-NM border area, defined border crossing points and military requirements make local flights close to the border particularly sensitive. The AIP explicitly recommends that no local routes with turning points directly on the border with Belarus or Russia should be planned in controlled airspace. Official source: AIP Lithuania GEN 1.2 / ENR 1.10
R, D and TSA areas may be activated at short notice. Therefore check AUP/UUP and NOTAM. Official source: AIP Lithuania ENR 5.1
At the time of research, there is a temporary NOTAM about possible GNSS jamming and spoofing disturbances, especially in the western and southern part of the Vilnius FIR. The NOTAM was planned at the time of research until 30.10.2026.
TEMPORARY - NO DUERREGEL This note is not treated as a permanent country rule. Prior to each flight, up-to-date NOTAM shall be checked with particular regard to GNSS interference.
The following officially proven current points are particularly relevant for flight preparation:
1 AIP/AIRAC Currently is main AIP AIRAC AMDT 003/2026, effective 11.06.2026; AIP VFR 80/26 Old expenses may not be reused.
2 The current AIP identifies controlled and uncontrolled airspace almost universally as TMZ. Old representations with transponder requirements only in certain controlled areas are therefore no longer reliable.
3 FIS sectorization has been changed. The 2025 published own Šiauliai information 124.455 sector no longer appears in the current ENR 2.1; For Kaunas, two different sector configurations with 124.530 / 124.605 are currently published.
4 An already adopted amendment to the Lithuanian Aviation Law will enter into force in essential UL-related parts only 31.12.2026. These future rules may not be presented prematurely as applicable law in a guide with stand August 2026.
5 VFR Supplements The current AIP VFR checklist currently shows NIL. This does not excuse the examination of the general AIP-SUP and the NOTAM.
Topic
Lithuania 2026
Schengen
Yes
Entry permit SEP, private
No
Border crossing
FPL required
Topic
Lithuania 2026
Class G without FPL
not to plan as a normal case - AIP also lists FPL for uncontrolled airspace
8.33kHz
Yes, mandatory
Transponder
A+C or Mode S practically nationwide
Class G
predominantly under FL095 outside controlled structures
TA
5.000 ft MSL
FL095 in Class G
Do not use VFR
VFR max.
Basically FL195
Night VFR SEP
Yes, with an EASA night rating and equivalent equipment
FIS Vilnius
123.855
FIS Palanga
125.730
FIS Kaunas
124.530 / 124.605 - Check sector
FPL confirmation
by calling Vilnius ARO
Close FPL without ATS
immediately at Vilnius ARO
SAR in the absence of a closure
after 30 min
UL approach
Confirm aircraft/license recognition in advance
UL flat-rate transponder-free
No - not derivable from AIP
Ornithological reserves
Generally not motorized under 1 km
ARO / Briefing
+ 370 706 94 694, H2 4
Emergency
121.500 MHz
18 Official sources
Oro navigacija/AIS Lithuania
National legislation
EU / SERA / EASA
Safety notice
This country overview serves the structured flight preparation. Prior to each flight, the current AIP/eAIP, AIP SUP, AUP/UUP, NOTAM, meteorological information, current aerodrome/VAC data and any required approvals shall be re-checked. In particular for UL, flights close to the border with Belarus/Russia as well as flights without Mode-S/A+C transponders, a prior regulatory clarification is required.
Official direct links
The AIP, supplements, NOTAM, weather and aerodrome data valid on the day of flight remain authoritative. Links open the respective official source in a new window.
This country guide supports individual flight preparation. It does not replace the AIP, AIP SUP, NOTAM, AUP/UUP, weather and aerodrome information valid on the day of flight.
Systematic reproduction, compilation or redistribution of the complete VFR Guide Europe is prohibited.