VFR Guide Europe

VFR Guide
Lithuania

Research date: 23.08.2026AIP AIRAC AMDT 003/2026 · AIP VFR AMDT 80/26 · effective 11 JUN 2026Information for flights under visual flight rules (VFR) in Lithuania.

At a glance

Cockpit brief – Lithuania

FIS

Kaunas Information

124.530 / 124.605 MHz · Palanga 125.730 · Vilnius 123.855

Transition altitude

5,000 ft MSL

Nationwide

VFR ceiling

FL195

Except in specifically suitable airspace

Transponder

Observe TMZ

Plan for altitude-reporting A/C or Mode S

Eastern border

Special rules

Recheck Belarus/Russia border, ADIZ and security information

01

Entry

Schengen and external borders with Belarus and Russia.

Read more →
02

Flight plan

Duty, task, activation and closure.

Read more →
03

FIS

Kaunas, Palanga and Vilnius Information.

Read more →
04

Airspace

Controlled areas, TMZ and border regions.

Read more →
05

VFR rules

VMC minima, minimum heights and FL195.

Read more →
06

altimeters

Transition Altitude, QNH and cruising altitudes.

Read more →
07

Night VFR

Requirements and special features at night.

Read more →
08

Transponders and radio

TMZ, Mode S or A/C and 8,33 kHz.

Read more →
09

UL Rules

National requirements for ultralight aircraft.

Read more →
10

Airfields

PPR, operating hours and local procedures.

Read more →
11

Nature protection

Bird migration and sensitive areas.

Read more →
12

Aviation weather

Official weather information and briefing.

Read more →
13

Specific features

GNSS incidents and operational information.

Read more →

Basis and topicality

The operational information was compiled using up-to-date official Lithuanian and European sources. Checked publication status: Main AIP AIRAC AMDT 003/2026, effective since 11.06.2026; AIP VFR AMDT 80/26, also effective since 11.06.2026. The AIP-VFR supplement page does not show any VFR supplements at the research status. General AIP SUP and NOTAM must nevertheless be checked route-related. Official source: Oro navigacija / AIS Lithuania - AIP, AIP VFR and Supplements

Entry requirements

Lithuania is an EU and Schengen state. In principle, a Lithuanian entry permit is not required for a private, non-commercial flight with a foreign civil aircraft. Liability insurance is required. Official source: AIP Lithuania GEN 1.2 - Entry, Transit and Departure of Aircraft

Entry from another Schengen State

For flights between Lithuania and other Schengen countries, the obligation to use an airfield with border, customs and other control points does not apply in principle. This applies as long as Lithuania does not reintroduce temporary controls at the Schengen internal borders. In the case of the actual border crossing, a distinction must be made:

  • in controlled airspace: border crossing through entry/exit/en route points foreseen by ATS;
  • in uncontrolled airspace vis-à-vis Schengen states: The state border can in principle be crossed at any point.

Thus, for example, a VFR entry from Poland or Latvia in uncontrolled airspace is not limited to individual border crossing points. Official source: AIP Lithuania GEN 1.2

Arrival from a non-Schengen country

For international arrivals or departures where border, customs or other controls are required, an aerodrome shall be used where the appropriate controls can be carried out. Particular caution is required on the borders with Belarus and Russia/Kaliningrad. In uncontrolled airspace, the border may only be crossed via published entry/exit/intermediate points. In addition, there is a 4-NM border area along the border with non-EU countries. For flights within this border area, the AIP basically requires:

  • Flight plan
  • Two-way radio
  • Mode A+C or Mode S
  • Military approval, as appropriate

For international flights that actually cross the border with a non-Schengen state, the AIP contains an exception to the military permit requirement mentioned therein; the remaining border and ATS procedures remain in place. Official source: AIP Lithuania GEN 1.2

General Declaration

GEN 1.2 contains General Declaration and, where applicable, Passenger and Cargo Manifesto for flights actually subject to border/customs/health clearance. Without passengers or cargo, only the General Declaration remains for this clearance. For the normal private intra-Schengen flight, there is no general obligation to routinely file a General Declaration. Official source: AIP Lithuania GEN 1.2

SEP

Private, non-commercial SEP flights do not require a general national entry permit. The usual European aircraft, license, medical and insurance requirements remain unaffected.

UL

The general AIP rule “no entry permit for foreign non-commercial civil aircraft” is also relevant for the flight operation. However, it does not automatically answer the question of recognition of a foreign national UL pilot license. Therefore, see separate chapter UL special schemes.

Flight plan

Compared to many other European countries, Lithuania has a relatively far-reaching schedule regime. According to ENR 1.10, an FPL is intended in particular for:

  • Each flight, or the portion of the flight for which ATC service is provided;
  • flights in the uncontrolled airspace of the Vilnius FIR to enable FIS, Alerting and SAR;
  • Flights in or through Prohibited, Restricted or Border Areas;
  • any international border crossing;
  • VFR night flights leaving the aerodrome environment.

For a pure flight within a published ATZ, ENR 1.10 does not require a flight plan. Official source: AIP Lithuania ENR 1.10 - Flight Planning

Practical consequence

For a typical Germany-Poland-Lithuania flight, an FPL is required for international entry into Lithuania at the latest. In addition, the Lithuanian AIP explicitly lists flights in uncontrolled airspace as FPL cases. One should therefore not assume the usual assumption in some other states that a pure Class-G flight without an FPL is easily possible.

Lead times

  • at the earliest 120 hours before EOBT;
  • at least 3 hours in advance when ATFM measures are possible;
  • otherwise at least 60 minutes before departure;
  • AFIL: in time for ATS to receive the plan at least 10 minutes before the planned entry into a Control Area.

Official source: AIP Lithuania ENR 1.10

Flight plan task

VFR flight plans can be submitted via Vilnius ARO, self-briefing or online via Oro navigacija. Vilnius ARO / Briefing

H2 4

phone

+370 706 94 694

Additional current briefing number

+370 610 25 217

e-mail

briefing@ans.lt

IMPORTANT After submitting the flight plan, the AIP expressly requires a call to Vilnius ARO to confirm that the FPL has actually been received. Oro navigacija – Flight Plan. Official source: AIP Lithuania ENR 1.10

Delay / Change

In the case of a controlled VFR flight, in the event of a delay of more than 30 minutes compared to EOBT the FPL must be changed or changed. be renounced. In the case of an uncontrolled flight, this threshold is 1 hour. Changes and cancellations must be notified to ATS. Official source: AIP Lithuania ENR 1.10

Activate and close flight plan

activation

The current sections ENR 1.10 and the AIP VFR examined do not describe an independent, generally applicable pilot-by-phone procedure, as is known from individual other states. For the specific question whether a pilot DEP/activation message is additionally required for a take-off from an unmanned aerodrome or operating site:

Before such a departure, the procedure should therefore be clarified with Vilnius ARO.

Close

After the landing, an Arrival Report must generally be done immediately. When landing at an aerodrome with ATS, an additional arrival message is not required unless explicitly requested by ATS. When landing without ATS, the flight plan shall be closed as soon as possible on the fastest available route at Vilnius ARO:

Vilnius ARO + 370 706 94 694

SEARCH AND RESCUE If 30 does not receive a flight plan closure message minutes after the expected completion, a search and rescue operation shall be initiated after the Lithuanian AIP.

Closing an FPL should therefore be one of the first actions immediately after landing. Official source: AIP Lithuania ENR 1.10

Flight Information Service - FIS

FIS for uncontrolled airspace is generally offered H2 4; Operating languages are Lithuanian and English. Official source: AIP Lithuania ENR 2.1

Current FIS channels

Area / Callsign

Channel

KAUNAS INFORMATION

124.530 / 124.605

Palanga Information

125.730

VILNIUS INFORMATION

123.855

Emergency

121.500

The duplicate entry for KAUNAS INFORMATION is not a clerical error: The current ENR 2.1 releases two Kaunas sector configurations with different lateral boundaries and different ATS locations - once 124.530, once 124.605. Therefore, one of the two channels may not be stored across the board for all Kaunas FIS; The current VFR map, sector boundary and, if applicable, NOTAM are relevant.

In an older 2025 he AIP version was still listed a separate ŠIAULIAI INFORMATION 124.455 sector. In the current ENR 2.1 of the 11.06.2026, this no longer appears as a separate FIS sector.

I could not verify a special air-to-air channel for motor flight/UL, which could be reliably adopted from the current official AIP.

Airspace structure

In the Vilnius FIR, the classes C, D and G are essentially used for the VFR operation relevant here. Classes A, B, E and F are not used in the Vilnius FIR. Typical structure:

  • outside published controlled areas below FL095: Class G;
  • Vilnius CTA FL095 - FL195: Class C;
  • Vilnius UTA FL195 - FL660: Class C;
  • Kaunas TMA: Class C;
  • Palanga TMA: Class C;
  • Vilnius TMA: Class C;
  • Šiauliai TMA: Class D.

Individual controlled airspace may become Class G in accordance with AIP when ATS is not operated. Therefore, the operating times of the respective structure must be checked. Official source: AIP Lithuania ENR 1.2 and ENR 2.1

Prohibited / Restricted / Danger / TSA

Lithuania has numerous EYP-Prohibited Areas, EYR-Restricted Areas, Danger Areas, TSA as well as militarily used and flexibly activated areas. A significant portion of military restricted areas will be activated through Airspace Management; Activations can be announced via NOTAM and AUP/UUP. Appropriate military approval is generally required for entry into Prohibited or Restricted Areas.

PRACTICAL NOTE For VFR flights through Lithuania, a static chart alone is insufficient. AUP/UUP and current NOTAM are mandatory parts of the route check. Official source: AIP Lithuania ENR 5.1

Visual flight rules

Lithuania applies the European SERA rules. Official source: AIP Lithuania ENR 1.2 / SERA

VMC minimums

Height

airspace

Flight visibility

Cloud separation

from FL100

C/D/G

8 km

1.500 m horizontally / 1.000 ft vertically

under FL100, above 3.000 ft

C/D/G

5 km

1.500 m / 1.000 ft

to 3.000 ft

C/D

5 km

1.500 m / 1.000 ft

to 3.000 ft

Basically 5 km

clear of cloud / surface in sight

Under special conditions approved by the Transport Competence Agency, reduced flight visibility is possible; This is not a general clearance for normal cruise flights.

Minimum flight altitudes

Except for take-off/landing or with special permission:

  • on cities, towns and gatherings of people: at least 1.000 ft above the highest obstacle within 600 m;
  • otherwise at least 500 ft over ground/water or 500 ft above the highest obstacle within 150 m.

Official source: AIP Lithuania GEN 1.7 / SERA

Special VFR

SVFR is possible within a CTR with ATC clearance. For aeroplanes, in particular:

  • in principle day-to-day operations, unless otherwise permitted by the competent authority;
  • clear of cloud;
  • surface in sight;
  • at least 1.500 m flight visibility;
  • maximum 140 KIAS;
  • for take-off/landing, or Approach in Circuit/ATZ no SVFR clearance at less than 1.500 m ground visibility or Ceiling below 600 ft.

Official source: AIP Lithuania GEN 1.7 / SERA

Maximum VFR flight altitude

According to SERA, VFR flights above FL195 are generally not permitted. Exceptions are only possible in airspace reserved for this purpose or with special ATS authorisation up to and including FL285. For normal SEP/UL cruises, therefore, FL195 is the practical upper VFR limit. Official source: SERA. 5005

VFR on top / over clouds

A separate Lithuanian ‘VFR-on-top’ procedure is not published in the AIP sections examined. Above the low Class-G layer, the normal SERA-VMC distances apply; in Class G in the lower layer, on the other hand, earth vision is expressly prescribed. Official source: AIP Lithuania ENR 1.2 / SERA

Altimeter setting and cruising altitudes

The transition altitude is in the entire Vilnius FIR 5.000 ft MSL. The Transition Level at international airports is usually broadcast via ATIS or communicated by ATC.

  • up to and including TA: QNH;
  • from transition level: 1013,2 hPa/QNE;
  • outside controlled airspace above 5.000 ft will be flown to QNE.

SPECIFIC FL095 shall not be used for VFR flights in uncontrolled Class G airspace. Official source: AIP Lithuania ENR 1.7

VFR semicircuit rule above 3.000 ft

Magnetic track

VFR level

000°-179°

FL035, 055, 075, 095...

180°-359°

FL045, 065, 085, 105...

In addition, the usable height depends on airspace sub-limits and terrain.

Night VFR

Night VFR is basically possible in Lithuania. For night VFRs, in particular:

  • flight plan when leaving the immediate vicinity of the aerodrome;
  • two-way communication on the appropriate ATS channel, where available;
  • Ceiling at least 1.500 ft;
  • the reduced VFR visual range controls shall not be used;
  • up to 3.000 ft MSL or 1.000 ft over terrain - whichever is higher - the surface must remain permanently visible;
  • Over high elevation, i.e. mountainous terrain at least 2.000 ft above the highest obstacle within 8 km;
  • otherwise at least 1.000 ft above the highest obstacle within 8 km.

Official source: AIP Lithuania GEN 1.7 / SERA Night VFR

SEP

For SEP, the EASA license requirements also apply. For the exercise of PPL/LAPL privileges under VFR at night, the corresponding night rating/night rating shall be under FCL. 810 is required. The equipment shall comply with applicable Part-NCO requirements, including night lighting and additional flight and navigation instrumentation. Official source: Part-FCL FCL. 810 and Part-NCO

UL

Whether and under what conditions a foreign-licensed UL with a foreign national UL license may carry out night VFR in Lithuania could not be clearly deduced from a currently applicable official Lithuanian regulation.

Before a UL night flight, a written clarification with TKA/LTSA is required.

Transponder

Virtually all of Lithuania’s controlled and uncontrolled airspace is designated as the Transponder Mandatory Zone (TMZ). Excluded are designated ATCs and special categories explicitly mentioned.

Generally required:

  • two-way VHF radio;
  • SSR transponder Mode A+C or Mode S.

The exceptions specifically mentioned concern, inter alia, flights exclusively within certain ATZs, sailplanes, motorised hang gliders, free balloons and simple aircraft. For certain exempt categories, an electronic identification solution recognised by Oro navigacija may alternatively be used in uncontrolled airspace. This shall not be considered a replacement in controlled airspace. Otherwise, an aircraft without an A+C/S shall only be operated with an appropriate approval from the ATS provider. Official source: AIP Lithuania GEN 1.2 and GEN 1.5

UL

The AIP does not mention “ultra-light aircraft” as a general transponder exception. Therefore, a foreign three-axle vehicle should under no circumstances assume that it is permitted to fly without a transponder solely on the basis of its UL approval. Whether a specific UL falls within the Lithuanian legal definition of a “simple aircraft”:

For a normal 472,5 -/ 600-kg triaxle, the safe practical planning is therefore: 8,33-kHz -radio + mode S or provide at least Mode A+C, as long as no written exception has been confirmed.

Squawk

The current main AIP ENR 1.6 publishes the international emergency codes 7500 / 7600 / 7700 and ATC-assigned codes. A single, unambiguously identifiable code as a universal Lithuanian VFR standard code, I could not reliably verify in the current main AIP.

Therefore use the code assigned by ATS or, before an uncontrolled flight, check the current VFR chart and AIP status. Official source: AIP Lithuania ENR 1.6

radio

For IFR and VFR flights within the Vilnius FIR/UIR, 8,33-kHz-capable VHF radio is required. In the flight plan, item 10 shall be marked with Y if appropriately equipped. The operating languages vis-à-vis ATC/FIS are English and Lithuanian. For a foreign pilot, English is therefore provided regularly. RMZ procedures follow SERA: On the published channel, listening shall be maintained and the required initial message dispatched before arrival. Official source: AIP Lithuania GEN 1.2, GEN 1.5 / SERA. 6005

UL special regulations

This section must be handled with particular care because UL is regulated nationally in Lithuania and an EASA SEP rule cannot be automatically transferred to UL.

Entry of the foreign UL

The AIP GEN 1.2 does not require a general flight permit for non-commercial flights of foreign civil aircraft.

In addition, the LTSA Regulation 2 BE- 252, applicable since 01.05.2025, provides for foreign aircraft of the Experimental Category, registered in an ICAO State, that they may be operated in Lithuania if:

  • they comply with the airworthiness and maintenance requirements of their State of Registry;
  • they are actually airworthy,
  • a valid certificate of airworthiness issued by the competent authority of the State of registry.

From this provision, it cannot be safely concluded solely on the basis of an MTOM of 472,5 kg or 600 kg that any German or other foreign UL can be automatically assigned to the Lithuanian “Experimental Category” and thus operated without further recognition.

For a specific UL, it should therefore be clarified in writing to TKA/LTSA which Lithuanian category it is assigned with registration, type, MTOM and airworthiness document before the first trip to Lithuania. Official source: AIP Lithuania GEN 1.2 LTSA Director Order 2 BE-252

472.5kg / 600kg

Lithuania has national arrangements for aircraft not fully regulated by EASA. A general official rule “all foreign 600-kg -UL are automatically recognized” could not be verified.

The MTOM alone is therefore not sufficient proof of an entry permit or recognition.

Recognition of the foreign UL pilot license

There is a particularly important legal situation here at the time of research: Lithuanian Aviation Law was amended by Law XV- 567; However, new provisions on UL/national licensing material only enter into force at the 31.12.2026. They may not yet be used as applicable law for a flight in August 2026. The currently consolidated version for 01.06.- 30.12.2026 confirms this transitional status. A publicly available regulation in force today, at the 23.08.2026, which clearly confirms an automatic short-term recognition of a foreign UL pilot licence, could not be robustly established.

Before a flight, a written confirmation from TKA/LTSA is therefore required to recognize the specific foreign license. Official source: Lithuanian Aviation Law, consolidated version 01.06.- 30.12.2026; Amendment Law XV-567

Medical

Since the current recognition of the foreign UL pilot licence could not be clearly proven, the automatic recognition of the respective national UL medical cannot be confirmed with certainty.

Insurance

A civil liability insurance of the aircraft operator is required according to GEN 1.2. A proof of insurance should be carried on board. Official source: AIP Lithuania GEN 1.2

Transponders and radio

There is no blanket exception for UL:

  • 8,33 kHz is required in principle;
  • A+C or Mode S is generally required as long as the specific UL does not demonstrably fall under an explicitly published exception.

Official source: AIP Lithuania GEN 1.5

ELT

Here, on the other hand, there is an expressly published special feature: GEN 1.5 exempts ultra-light aircraft from the general obligation there to carry an ELT on 121,5 MHz and 406 MHz. This exception concerns only this specific AIP-ELT rule and cannot be interpreted as a blanket exemption from other possibly applicable equipment rules. Official source: AIP Lithuania GEN 1.5

UL night flight

No SEP night flight rule automatically transferred to UL.

Practical recommendation for a foreign UL

Before the first Lithuanian flight, have it confirmed in writing:

  • Recognition of the specific aircraft/certification;
  • recognition of the pilot licence;
  • recognition of the medical;
  • 472,5 -/ 600-kg category classification;
  • transponder status if A+C/S/Mode-S equipment is not available;
  • night rating, where applicable.

Airfields

Conditions vary considerably between international commercial airports and smaller airports. Therefore, PPR, operating hours, UL approval, customs, handling or parking facilities may not be derived from a general country rule. Before each flight, the AD section or Check current VFR airfield map and NOTAM. For example, Vilnius International: For incoming General Aviation flights, PPR is provided in principle; Ground handling must be coordinated before the PPR registration, and PPR coordination is generally carried out at least 24 hours before. For VFR flights in Vilnius TMA/CTR, the current AD page also requires FPL, ATC-Clearance at the latest 5 minutes before arrival and continuous two-way radio. Similar VFR methods also exist in Palanga, for example. UL: Whether a particular aerodrome accepts foreign UL must be based on its current AD/VFR publication. be checked directly with the operator. A nationwide release of all airfields for foreign UL could not be verified. Official source: AIP Lithuania AD 2 EYVI and EYPA

Nature conservation / bird migration

In ENR 5.6, Lithuania explicitly refers to significant migratory activity, especially on the Baltic Sea coast and the Curonian port. Particularly intense periods are:

  • end of March to beginning of May;
  • July/August;
  • End of August to October.

A significant proportion of migration occurs at night and can reach altitudes of several thousand metres. Official source: AIP Lithuania ENR 5.6

Ornithological protected areas

NATIONAL SPECIFICITY In the published ornithological protected areas, motor-powered aircraft are in principle prohibited from flying below 1 km altitude; Excluded are certain governmental, SAR and emergency operations.

The protected areas are mapped in ENR 6.10. For VFR flights, this national 1-km rule is much stricter than the normal SERA minimum flight altitude and therefore must be taken into account in the route planning. Official source: AIP Lithuania ENR 5.6 / ENR 6.10

Aviation weather

The official meteorological service for civil aviation is the Lithuanian Hydrometeorological Service (LHMS). Aviation Forecast / Briefing: +370 648 05 448 and +370 648 06 768. The service provides METAR, TAF, SIGMET, AIRMET, low-level forecasts and consultation. For non-scheduled flights within Europe, GEN 3.5 specifies advance notice of generally 3 hours for specially requested consultation or flight documentation. LHMS Aviation Weather. Official source: AIP Lithuania GEN 3.5

Other country-specific features

Practically nationwide TMZ

The most important special feature for foreign VFR pilots is the very extensive transponder and radio obligation also in Class-G airspace. “Staying under controlled airspace and flying on without a transponder” is basically not a robust strategy in Lithuania. Official source: AIP Lithuania GEN 1.2

Belarus/Russia border

The 4-NM border area, defined border crossing points and military requirements make local flights close to the border particularly sensitive. The AIP explicitly recommends that no local routes with turning points directly on the border with Belarus or Russia should be planned in controlled airspace. Official source: AIP Lithuania GEN 1.2 / ENR 1.10

Military airspace

R, D and TSA areas may be activated at short notice. Therefore check AUP/UUP and NOTAM. Official source: AIP Lithuania ENR 5.1

GNSS interference

At the time of research, there is a temporary NOTAM about possible GNSS jamming and spoofing disturbances, especially in the western and southern part of the Vilnius FIR. The NOTAM was planned at the time of research until 30.10.2026.

TEMPORARY - NO DUERREGEL This note is not treated as a permanent country rule. Prior to each flight, up-to-date NOTAM shall be checked with particular regard to GNSS interference.

What to check against older information in particular or. to be updated:

The following officially proven current points are particularly relevant for flight preparation:

1 AIP/AIRAC Currently is main AIP AIRAC AMDT 003/2026, effective 11.06.2026; AIP VFR 80/26 Old expenses may not be reused.

2 The current AIP identifies controlled and uncontrolled airspace almost universally as TMZ. Old representations with transponder requirements only in certain controlled areas are therefore no longer reliable.

3 FIS sectorization has been changed. The 2025 published own Šiauliai information 124.455 sector no longer appears in the current ENR 2.1; For Kaunas, two different sector configurations with 124.530 / 124.605 are currently published.

4 An already adopted amendment to the Lithuanian Aviation Law will enter into force in essential UL-related parts only 31.12.2026. These future rules may not be presented prematurely as applicable law in a guide with stand August 2026.

5 VFR Supplements The current AIP VFR checklist currently shows NIL. This does not excuse the examination of the general AIP-SUP and the NOTAM.

Cockpit summary

Topic

Lithuania 2026

Schengen

Yes

Entry permit SEP, private

No

Border crossing

FPL required

Topic

Lithuania 2026

Class G without FPL

not to plan as a normal case - AIP also lists FPL for uncontrolled airspace

8.33kHz

Yes, mandatory

Transponder

A+C or Mode S practically nationwide

Class G

predominantly under FL095 outside controlled structures

TA

5.000 ft MSL

FL095 in Class G

Do not use VFR

VFR max.

Basically FL195

Night VFR SEP

Yes, with an EASA night rating and equivalent equipment

FIS Vilnius

123.855

FIS Palanga

125.730

FIS Kaunas

124.530 / 124.605 - Check sector

FPL confirmation

by calling Vilnius ARO

Close FPL without ATS

immediately at Vilnius ARO

SAR in the absence of a closure

after 30 min

UL approach

Confirm aircraft/license recognition in advance

UL flat-rate transponder-free

No - not derivable from AIP

Ornithological reserves

Generally not motorized under 1 km

ARO / Briefing

+ 370 706 94 694, H2 4

Emergency

121.500 MHz

18 Official sources

Oro navigacija/AIS Lithuania

  • AIP Lithuania - GEN 1.2 Entry, Transit and Departure of Aircraft
  • AIP Lithuania - GEN 1.5 Aircraft Instruments, Equipment and Flight Documents
  • AIP Lithuania - GEN 1.7 Differences / SERA Night VFR / Special VFR
  • AIP Lithuania - ENR 1.2 Visual Flight Rules
  • AIP Lithuania - ENR 1.6 ATS Surveillance Services
  • AIP Lithuania - ENR 1.7 Altimeter Setting Procedures
  • AIP Lithuania - ENR 1.10 Flight Planning
  • AIP Lithuania - ENR 2.1 FIR/UIR/TMA/CTA and FIS sectors
  • AIP Lithuania - ENR 5.1 Prohibited/Restricted/Danger Areas
  • AIP Lithuania - ENR 5.6 Bird Migration and Sensitive Fauna
  • AIP Lithuania - GEN 3.5 Meteorological Services
  • AIP VFR Lithuania / Supplements
  • Oro navigacija - Flight Plan
  • LHMS Aviation Weather

National legislation

  • LTSA Director Order 2 BE- 252 from 23.12.2024, valid since 01.05.2025 - Experimental Category Airworthiness and Maintenance
  • Lithuanian Aviation Law - consolidated version 01.06.- 30.12.2026
  • Amendment Law XV- 567 with phased entry into force dates

EU / SERA / EASA

  • Commission Implementing Regulation (EU) No 923/2012 — SERA
  • Part-FCL FCL. 810 Night Rating
  • Part-NCO - VFR night flight equipment

Safety notice

This country overview serves the structured flight preparation. Prior to each flight, the current AIP/eAIP, AIP SUP, AUP/UUP, NOTAM, meteorological information, current aerodrome/VAC data and any required approvals shall be re-checked. In particular for UL, flights close to the border with Belarus/Russia as well as flights without Mode-S/A+C transponders, a prior regulatory clarification is required.

Important notice:

This country guide supports individual flight preparation. It does not replace the AIP, AIP SUP, NOTAM, AUP/UUP, weather and aerodrome information valid on the day of flight.

Systematic reproduction, compilation or redistribution of the complete VFR Guide Europe is prohibited.