VFR Guide Europe

VFR Guide
Denmark

Research date: 23.08.2026Naviair AIP / VFR Flight Guide Denmark · TrafikstyrelsenInformation for flights under visual flight rules (VFR) in Denmark.

At a glance

Cockpit brief – Denmark

FIS

Copenhagen Information

Sector-dependent, including 127.080 · 129.475 · 124.000 MHz

Bornholm

Sweden FIR

Also prepare current Swedish ATS and airspace procedures

Transition altitude

Normally 3,000 ft

5,000 ft in Copenhagen Area

Foreign UL

Prior permission

Trafikstyrelsen permission and supporting documents

UL operation

Sunrise to sunset

Maximum 9,500 ft MSL and individual permit conditions

01

Entry

Schengen, Customs, Airport of Entry, SEP and UL.

Read more →
02

Flight plan

Border flight, abandonment, activation and closure.

Read more →
03

FIS

Copenhagen Information, Air-to-Air and Bornholm.

Read more →
04

Airspace

Classes C, D, E and G and TMZ/RMZ.

Read more →
05

VFR rules

VMC minima and minimum heights.

Read more →
06

altimeters

Transition altitude and QNH procedures.

Read more →
07

Night VFR

SEP Rules; UL Sunrise Sunset only.

Read more →
08

Transponders and radio

SSR, 8,33 kHz, RMZ and Air-to-Air.

Read more →
09

UL Rules

Entry permit, documents and operational limits.

Read more →
10

Airfields

PPR, customs, UL permissibility and local procedures.

Read more →
11

Nature protection

Sensitive areas and operational consideration.

Read more →
12

Cockpit list

SEP, UL and Bornholm compact.

Read more →

Basis and topicality

This country overview has been prepared in a print- and cockpit-friendly format. The operational statements in the underlying country text were reassessed using current official Danish and European sources.

Current status

Naviair will introduce the digital Danish aeronautical charts in August 2026 with the latest AIRAC status. Temporary airspaces and local procedures can still change at short notice and must be checked via AIP SUP and NOTAM before each flight.

Entry requirements

Denmark is part of the EU and the Schengen area. For aviation, this does not mean that every airport can be used for an international flight without further requirements. The first landing in Denmark or the last take-off from Denmark must take place at an airfield or heliport published for international traffic in accordance with the conditions of the current AIP/VFG. ● Schengen: There are generally no regular personal border controls between Schengen states.

● Customs: Customs and reporting procedures are to be considered separately and according to the current one

AD/AIP publication to be checked. ● Airport of Entry: The usable international places and pre-registration conditions are in AIP/VFG AD 1.3

as well as on the respective AD page.

SEP

Private flights with foreign civil aircraft from Chicago Convention states can generally be carried out without a special Danish entry permit. The published entry, customs, flight plan and airport procedures remain unaffected.

UL

National regulations apply to foreign-registered ultralight aircraft. Prior approval from the Danish Aviation Authority is required; For details see chapter UL special regulations.

Pure overflight without landing In principle, no special overflight permit is required for civil aircraft from states of the Chicago Convention and the Transit Agreement. However, according to the current information from the authorities, for certain overflights only, an advance notification to info@trafikstyrelsen.dk is required no later than 48 hours before the expected FIR border crossing. Before the flight, the current official publication is decisive.

Liability insurance There must be insurance cover for the overflight and landing in accordance with Regulation (EC) No. 785/2004. The following minimum coverages apply to liability towards third parties:

MTOM minimum coverage

under 500 kg 0.75 million SDR

under 1,000 kg 1.5 million SDR

under 2,700 kg 3 million SDR

under 6,000 kg 7 million SDR

In addition, the insurance requirements under Union law apply to passengers, luggage and, if applicable, freight. Proof of insurance is particularly relevant for UL approvals.

Flight plan

A VFR flight plan is particularly necessary for:

● Cross-border flights across the København FIR border or Danish border

Territory, unless a published exception applies, ● flights by a FIZ,

● VFR night flights when leaving the area around the airport,

● Flights or flight segments for which ATC service is required; for a limited controlled section

According to SERA, a shortened flight plan transmission to ATS may be possible.

Cross-border VFR flight

For a normal international VFR flight to Denmark, a complete ICAO flight plan should generally be submitted, unless a currently published special regulation clearly applies.

Special regulation Germany - Denmark The current Danish VFR publication contains a special daily VFR regulation for flights between Sønderborg (EKSB) and certain German border airfields. The Danish places Ærø and Tønder, which were previously additionally mentioned in older editions, may not be assumed to be part of this exception without a new current examination. ● Flensburg/Schäferhaus (EDXF)

● Heide-Büsum (EDXB)

● Husum (EDXJ)

● Kiel-Holtenau (EDHK)

● Leak (EDXK)

● Rendsburg/Schachtholm (EDXR)

● St. Michaelisdonn (EDXM)

● Westerland/Sylt (EDXW)

● Wyk auf Föhr (EDXY)

Practice

Before using the exception, immediately check ENR 1.10, the current VFR chart, SUP and NOTAM. The information to be reported to the ATS includes at least registration number/pattern, departure point and time, destination, flight time, endurance, people on board and name of the PIC.

Submit flight plan

Naviair operates the Danish ATS briefing and flight planning service. The SERA lead time of 60 minutes generally applies to international flight schedules, unless otherwise published regulations apply. ● Central ATS Briefing Office Denmark: +45 32 47 82 72

● Electronic flight plan submission and briefing via the online services currently provided by Naviair.

Activate and close flight plan

After takeoff, a departure message must be sent unless ATS has clearly determined the departure through radio communication or visual observation. After landing, an arrival message is required if ATS could not automatically determine the arrival.

Uncontrolled airport / no ARO ● Central ATS briefing / flight plan: +45 32 47 82 72

● ACC København / Close flight schedule: +45 32 46 23 38

Unclosed flight schedule

An open flight plan can lead to unnecessary alerting and search and rescue efforts. Actively ensure arrival notification at uncontrolled places.

Flight Information Service - FIS

The national flight information service is provided by Copenhagen Information / København Information. The relevant frequency depends on the sector and must be taken from the current VFR map.

Frequency range

large parts of eastern/central Denmark 127.080 MHz

western/southwestern areas 129.475 MHz

North Sea range 124,000 MHz

Air-to-Air ● General operational air-to-air communications up to FL100: 129.805 MHz

● UL / Hangglider: 130,130 MHz

● Over the North Sea and Skagerrak within København FIR always listen to 121,500 MHz, unless it is on

a different VHF frequency.

Bornholm

Special feature of Bornholm

Bornholm belongs to Denmark, but is within the Sweden FIR in terms of aviation. For flights to Bornholm, the current Swedish ATS and airspace procedures must also be taken into account.

Airspace structure

Within København FIR, ICAO airspace classes C, D, E and G are mainly used for VFR traffic. The vertical structure varies regionally. Typical elements are CTR, TMA, CTA, FIZ, RMZ, TMZ, LTA as well as Restricted, Danger and military areas.

FIZ / RMZ A Danish FIZ is also an RMZ. Before flying in, a two-way radio connection must always be established with the responsible AFIS office. In addition, published areas of airspaces E and G are designated as RMZ.

TMZ

In a TMZ, an altitude reporting transponder must be operated in Mode A/C or Mode S, unless a published exception applies.

Speed ​​Below FL100, the SERA speed limit of 250 KIAS generally applies, unless a permissible exception or ATC approval applies.

Visual flight rules

The basis is SERA and the supplementary Danish regulations.

VMC minima altitude / range flight visibility cloud distance

from FL100, C/D/E/G 8 km 1,500 m horizontal / 1,000 ft vertical

below FL100, above 3,000 ft MSL or 1,000 ft 5 km 1,500 m / 1,000 ft AGL

below, C/D/E 5 km 1,500 m / 1,000 ft

below, G basically 5 free of clouds, visibility km

Special VFR Without SVFR clearance, a VFR flight may not be carried out within a CTR if the published VMC conditions are not met. The respectively published Danish minimum values ​​and the SERA requirements apply to SVFR; fly clear of clouds and with a view of the earth. ● Daily VFR period: published lower limits including ceiling 600 ft / visibility 1.5 km.

● Outside the daytime VFR period: more stringent published conditions; Check current AIP/VFR Guide.

● Speed: generally a maximum of 140 KIAS according to SERA for SVFR.

VFR on top / without visibility of the earth The Danish publication refers to BL 5-61 for VFR flights without visibility of the earth's surface. This does not result in a blanket ban on VFR on top; the additional conditions there and the general VMC, airspace and operating regulations must be met.

Minimum flight altitudes

● Above cities, densely populated areas, holiday/camping areas and crowds of people: at least

1,000 ft above the highest obstacle within 600 m. ● Other areas: at least 500 ft above ground/water or 500 ft above the highest obstacle

within 150 m.

Maximum VFR flight altitude

VFR flights within København FIR are normally only permitted up to and including FL195. Above FL195, special permission from the Danish Aviation Authority is required.

Altimeter setting

● Transition Altitude København FIR: 3,000 ft MSL

● Copenhagen Area: 5,000 ft MSL

● Transition Level: not fixed; depending on the QNH and announced by ATS.

Above Transition Altitude, published VFR cruise altitudes corresponding to magnetic heading are used unless ATC or AIP specifies otherwise.

Night VFR

SEP

Night VFR is generally permitted in Denmark. A flight plan is required when leaving the area around the airport. In addition, the requirements of SERA, Part-FCL, Part-NCO and the Danish BL 5-61 apply. ● For non-local night VFR, the Danish regulation requires, among other things, sufficient visibility and

Cloud bases along the route, destination and alternative airport must be taken into account. ● The pilot requires the night flight rating required by Part-FCL.

● The aircraft must be appropriately equipped for night VFR.

UL

UL: Night flights not permitted

BL 9-6 restricts UL operations to VFR between Sunrise and Sunset.

Transponder

For VFR flights in appropriately published Danish ATS airspace and in TMZ, an operational altitude reporting transponder is required. If an operational transponder is installed, it must generally be operated during the flight unless a published exception applies.

Code meaning

7000 VFR standard code without individual assignment

7500 illegal interference

7600 radio interference

7700 emergency

An individually assigned squawk does not automatically mean radar surveillance and does not replace required airspace clearance.

radio

8,33-kHz Channel grid For flights in airspace with mandatory radio carriage, the airborne radio equipment must in principle be 8,33-kHz-capable, unless a published exception applies.

RMZ

In an RMZ, radio and listening are required; Two-way radio contact must always be established before entry. The initial call includes at least station, call sign, aircraft type, position, altitude and intent.

Language For international VFR flights, English is the practical standard language. In the UL approval process, the Danish authorities require proof of an international radio license and the required language skills.

UL special regulations

Entry of foreign UL

Prior approval required

The older information, according to which written entry permission must be obtained from the Danish UL association DULFU, can no longer be used as the current rule for foreign UL. The Danish Civil Aviation and Railway Authority / Trafikstyrelsen is responsible.

Weight / 600-kg topic The current authority information describes the approval process explicitly for foreign UL with MTOM under 600 kg. For an aircraft with exactly 600,0 kg MTOM, this formulation is not clear.

Exactly 600.0 kg

Approval ● tied to the specific pilot and the specific aircraft,

● only valid for the approved period,

● according to the current information from the authorities, limited to a maximum of 90 days in total,

● Processing fee according to the currently published official information: DKK 500.

Required documents ● Medical,

● international radio authorization and language proficiency,

● registration certificate,

● airworthiness document,

● Proof of insurance in accordance with Regulation (EC) No. 785/2004,

● noise certificate,

● desired operating period and contact details.

UL operating rules

● Time of day: Sunrise to sunset.

● Flight visibility: in the uncontrolled areas specified by BL 9-6 at least 5 km.

● Populated areas: special overflight restrictions; horizontal distance at least 150 m according to BL 9-6.

● Maximum Altitude: 9,500 ft MSL.

● Controlled airspace: only with the required ATC clearance.

● UL Air-to-Air: 130,130 MHz.

Airfields

For each Danish airfield, the current AD page, VFR VAC and NOTAM are authoritative. Depending on space, PPR, operating hours, AFIS/FIZ, customs/immigration PN, handling, UL restrictions, parking rules and local reporting points may apply.

International first/last exit

For international flights, also check AD 1.3 and the specific seat publication. A permanently fixed list of airports of entry is not practical for an updateable guide.

At the time of research 23.08.2026, an AIP/VFG SUP on temporary restricted areas along the German-Danish border is relevant. Areas shall be activated by NOTAM; when activated, the entry is only permitted under the published approval procedure. EKR6 64 to EKR6 68

● Vertical: SFC - 1,000 ft MSL

● Period of validity of the published SUP: 01.10.2025 to 01.10.2026

At the time of research, there is also a temporary SUP for several temporary Danger Areas due to drone activities around offshore installations in the North Sea. The actual activity is published via NOTAM. Valid: 01.06.2026 to 31.08.2026

● Period: daily 0600-1800 UTC

● Vertical: SFC - 1,400 ft MSL

Temporary

These details are not permanent country rules. After the SUP expires, they must be removed from the guide or re-evaluated.

Nature conservation and sensitive areas

The Danish VFR maps mark areas with sensitive fauna. Flying over designated sensitive areas below 1,000 ft should be avoided. The exact location can be found on the current aeronautical map.

Current status: 23.08.2026

For foreign ultralight aircraft: obtain permission through Trafikstyrelsen.

Copenhagen Information East: 127.080 MHz.

Air-to-Air: 129.805 MHz.

UL Air-to-Air: 130.130 MHz.

The current publication names Sønderborg for the special FPL rule.

Schengen identity checks, customs and Airport-of-Entry procedures must be assessed separately.

Transition Altitude: 3,000 ft; Copenhagen: 5,000 ft.

Ultralight aircraft may operate only between sunrise and sunset.

Maximum altitude for ultralight aircraft: 9,500 ft MSL.

Cockpit summary

SEP to Denmark ● select international place according to AD 1.3 / AD page,

● submit an international flight plan, unless a current exception applies,

● Check customs/immigration PN of the specific place,

● Check NOTAM and SUP,

● use current Naviair VFR map,

● Determine FIS sector frequency from the current map.

UL to Denmark

● obtain prior approval from the tobacconists,

● Carry permit and required documents,

● only Sunrise-Sunset,

● maximum 9,500 ft MSL,

● Observe UL-specific visibility and overflight rules,

● Check airfield for UL approval and PPR.

Border / Bornholm

● particularly check current EKR activations at the German-Danish border,

● additionally prepare Swedish FIR/ATS procedures for Bornholm.

Important contacts

Make contact

Naviair - Aeronautical Information Management Naviair Allé 1, DK-2770 Kastrup +45 32 47 82 21 aim@naviair.dk

Central ATS Briefing Denmark +45 32 47 82 72

ACC København - Close flight schedule / ATS +45 32 46 23 38

Danish Civil Aviation and Railway Authority / info@trafikstyrelsen.dk Trafikstyrelsen

Official sources

Essential chapters: AIP/VFG GEN 1.2, GEN 3.1, GEN 3.3, GEN 3.4, ENR 1.2, ENR 1.4, ENR 1.6, ENR 1.10, ENR 5.1, AD 1.3 as well as current VFR maps, AIP SUP and NOTAM. • Naviair AIM - AIP / VFR Flight Guide Denmark • Naviair - Charts / current aeronautical charts • Danish Civil Aviation and Railway Authority - Flight Operations • Trafikstyrelsen - Regulations for Civil Aviation / BL • EASA - Easy Access Rules / SERA • EUR-Lex - Implementing Regulation (EU) No. 1079/2012

Safety notice

Check again before every flight

This country overview is intended for VFR flight preparation, but does not replace the check of AIP/eAIP, AIP SUP, NOTAM, current VFR chart, weather briefing, airport information and any necessary official approvals required immediately before the flight. Frequencies, temporary or military airspaces, customs/immigration procedures and operating times must be checked before each flight against the latest official publications.

Important notice:

This country guide supports individual flight preparation. It does not replace the AIP, AIP SUP, NOTAM, AUP/UUP, weather and aerodrome information valid on the day of flight.

Systematic reproduction, compilation or redistribution of the complete VFR Guide Europe is prohibited.