Entry
Not in SchengenConfirm Airport of Entry and border/customs availability in advance
VFR Guide Europe
At a glance
Confirm Airport of Entry and border/customs availability in advance
136.000 MHz · alternative 129.725 MHz
Normally file at least 60 minutes before departure
English in controlled airspace; verify current frequencies
Clarify licence and aircraft status, especially at 600 kg, with the CAA in writing
CT-SERA, CT-LPULM and amendments 2025.
Read more →Non-Schengen, Airport of Entry and border clearance.
Read more →Coverage and English proof.
Read more →Border flight, home briefing, activation and closure.
Read more →Chișinău FIS and sectoral ATS frequencies.
Read more →CTR/TMA, Restricted, Danger and Reserved Areas.
Read more →VMC minima, minimum heights and FL195.
Read more →CT-SERA conditions and UL restrictions.
Read more →TA, QNH and cruising levels.
Read more →SSR, TMZ, 8,33 kHz and language.
Read more →Foreign license and recognition procedure.
Read more →Border clearance, PPR and local procedures.
Read more →Border flight, FPL, radio, transponder and UL.
Read more →The flight operations statements were rebuilt on the basis of current official Moldovan sources.
Current state of regulation: Since 05.10.2025, significant changes apply to the use of Moldovan airspace. CT-SERA Edition 02 is valid since 16.09.2025; for motorized ultralight aircraft, CT-LPULM Edition 01 applies since 17.04.2025.
Particularly important: Moldova is not a Schengen state. International flights are therefore to be planned with border formalities, flight plan and a border crossing point suitable for the specific flight.
Moldova is neither an EU member nor a Schengen member. International flights are therefore not to be treated as pure Schengen internal flights. Border and, where appropriate, customs formalities must be carried out at an authorised border crossing point. The Moldovan Border Police operates international airports or border crossing points in Chișinău, Bălți, Cahul and Mărculești, among others. For practical flight planning, however, it is crucial whether the respective seat is currently open for international general flights and operationally usable.
Airport of Entry Yes. When crossing international borders, an appropriate international border crossing aerodrome is required. For the specific flight, current AIP-AD page, NOTAM, opening hours and availability of border police and customs must be checked.
General Declaration For a general obligation to ICAO General Declaration on every private SEP or UL flight, no clear current rule could be derived in the underlying country text.
Since 28.02.2025 changed minimum insurance sums apply. For non-commercial aircraft with an MTOM up to and including 2.700 kg, the minimum passenger liability coverage is 151.880 SDR per passenger.
The operator must have a valid proof of insurance for each flight and be able to prove the legal minimum requirements. For the entry, an insurance confirmation with cover sums should be carried if possible in English.
Since the amendment to the 05.10.2025 Government Decision 870/2020 became effective, the previous idea that a VFR flight plan is only necessary for individual controlled or cross-border flights is no longer sufficient for Moldova. For a manned civilian flight, the operator must in principle have valid civil liability insurance, if necessary, the relevant permits and have submitted a flight plan to ATS, unless the flight is operated within a specially reserved airspace.
Duty periods Flight type Minimum lead
Cross-border VFR flight usually at least 60 minutes before departure
Domestic VFR flight at least 30 minutes before departure
ATFM relevant flight at least 3 hours before EOBT
Electronic flight plan filing MOLDATSA operates the official HomeBriefing service. Among other things, it provides PIB, weather documentation, flight plan management and ATFCM information. For LUKK Chișinău and LUBM Mărculești, pre-flight information is provided through the EEAS system.
After the landing of a flight to which the flight plan applies to the destination aerodrome, an arrival notification shall be sent to the appropriate ATS unit as soon as practicable. A separate arrival report shall not be required if ATS is available at the destination aerodrome and it is clearly established by radio or other signals that ATS has observed the landing. When landing at an aerodrome without ATS, the flight plan shall be closed as soon as possible via the fastest available means of communication. Where appropriate communication is not available on the ground, CT-SERA shall, as far as practicable, send a message to ATS immediately prior to landing.
The responsible air navigation service is MOLDATSA within the CHIȘINĂU FIR. The specific frequency to be used depends on the area, altitude and current ATS sectoring.
Service Frequency / Channel
CHIȘINĂU FIS 136.000 MHz
Service Frequency / Channel
Alternative FIS frequency 129.725 MHz In addition, there are several ACC frequencies. Before the flight, AIP ENR 2.1, current map and NOTAM must be checked. A frequency mentioned in the guide does not replace a current frequency check.
The Moldovan CAA describes the national airspace essentially with the classes C and G. The en-route airspace is in principle from FL055 class C; underneath are large areas of class G. Around controlled airfields, TMA and CTR structures extend significantly deeper.
Particularly important for VFR pilots: FL055 is not automatically the lower limit of controlled airspace everywhere. Around Chișinău and other controlled airfields, controlled airspace extends much deeper. Restricted, danger, reserved and segregated areas shall be checked for activity and access conditions before and during the flight.
With CT-SERA Edition 02, Moldova largely uses the well-known SERA principles.
Altitude/airspace Flight visibility Cloud spacing
from 10.000 ft AMSL 8 km 1.500 m horizontally / 1.000 ft vertically
below 10,000 ft and above 3,000 ft AMSL: 5 km; 1,500 m horizontally / 1,000 ft vertically, or 1,000 ft AGL
low in class G in principle 5 free from clouds and ground visibility km Under certain conditions provided by ATS, reduced visibility is allowed in class G. This exemption should not be used as a regular operating standard for voyage planning.
VFR flights are generally not allowed above FL195. Exceptions are only possible within correspondingly reserved airspace or on the basis of published ATS procedures. For normal travel VFR planning, FL195 is therefore considered a regular upper limit.
VFR cruising levels Above 3.000 ft AGL, unless ATC or a CAA permit provides otherwise, the VFR cruising levels matching the flight direction are to be used.
Special VFR Special VFR within a CTR requires an ATC release. In principle, the following apply, inter alia: free from clouds, permanent visual contact to the surface and for aircraft at least 1.500 m flight visibility. ATC shall not release Special VFR at the relevant aerodrome, inter alia, if the reported ground visibility is below 1.500 m or the Ceiling is below 600 ft.
Night VFR is not generally prohibited. CT-SERA provides for the possibility of allowing night VFR by ATS. • When leaving the airfield environment: flight plan. • Two-way communication with the competent ATC unit, if available. • Ceiling at least 1.500 ft. • The normal reliefs for reduced visibility in deep class G airspace do not apply at night. • At low altitude, the surface must remain constantly visible. Minimum night VFR height: in mountainous/high terrain at least 2.000 ft above the highest obstacle within 8 km; otherwise at least 1.000 ft above the highest obstacle within 8 km.
For UL, a night rating shall not be automatically derived therefrom. A secured general night VFR clearance for foreign UL was not found in the underlying country text.
CT-SERA uses the usual system from Altitude/QNH below the Transition Altitude and Flight Levels above. A robust, current transition altitude valid nationwide could not be verified in the underlying country text.
If a functional SSR transponder is present on board, it shall be used according to the underlying CT-SERA text throughout the flight, regardless of whether the aircraft is inside or outside an airspace subject to SSR. IDENT is only used on request by ATS.
situation code
Emergency 7700
Radio Failure 7600
Unlawful Interference 7500 Current TMZ or other mandatory transponder areas can be found in the AIP and the current map.
Since the change of October 2025 in controlled airspace radio traffic in English applies. Outside controlled airspace, Romanian, English or Russian can be used according to the underlying country text, provided the corresponding language authorization is available. For 2025, the CAA documents the implementation of the 8,33-kHz channel grid in the FIR Chișinău. For international VFR flights, a 8,33-kHz-capable radio device must therefore be planned. The actual channels to be used must be taken from the current AIP.
SEP - Special features For a normal private SEP flight apply in particular: • Flight plan. • Adequate liability insurance. • Border and customs clearance on international flights. • Current aircraft documents. • Valid pilot license and medical. • Compliance with CT-SERA rules as well as radio and transponders in accordance with the intended airspace. Moldova has largely based its pilot licensing law on EU Regulation 1178/2011 / Part-FCL and Part-MED. An additional Moldovan validation of a normal foreign ICAO/EASA PPL for a private flight with a properly foreign registered SEP has not been demonstrated as a general obligation in the underlying country text.
This area differs significantly from the SEP. Moldova has introduced 2025 with CT-LPULM Edition 01 a new set of rules for pilots of motorized ultralight aircraft without a type certificate. It has been valid since 17.04.2025.
A pilot with an UL licence issued by another state may only hold a ULM in Moldova under CT-LPULM if he holds a valid Certificate of Recognition from the Moldovan CAA. The CAA can grant general recognition for the UL licenses of a particular state. This is published by decision of the CAA director.
Medical CT-LPULM lists as accepted Medicals Class 1, Class 2 or LAPL Medical. In the case of a foreign UL license, the certificate of recognition, the underlying license and the corresponding medical are to be carried.
472,5 kg / 600 kg The current Moldovan regulations use their own national classification system for light and ultralight aircraft without a type certificate. A current official source, which clearly shows that a 600-kg -UL licensed abroad can fly into Moldova without individual or general recognition, was not found in the underlying country text.
The CAA lists two certified international airfields. MOLDATSA provides its complete home briefing in particular for LUKK Chișinău and LUBM Mărculești.
ICAO aerodrome / Note
LUKK Chișinău - Examining international GA procedures in advance using AIP/NOTAM
LUBM Mărculești - current usability, PPR/handling and border clearance checking details of PPR, handling, operating hours, fuel or parking are deliberately not presented as permanently valid. They shall be checked before each flight from AIP AD, NOTAM and through contact with the aerodrome. This is especially true for UL.
Official source for pre-flight information is MOLDATSA AIM / HomeBriefing. HomeBriefing contains NOTAM/PIB, MET documentation, flight plans and ATFCM information. The service is offered H2 4.
Authorities and important contacts Task / Contact
MOLDATSA AIM AIP products, AIRAC, NOTAM, HomeBriefing, ARO / Flight Plan Operations, METEO
CAA Republic of Moldova Aviation Authority; Flight Authorization: dri@caa.gov.md
Border Police Republic of Moldova Green Line 24/7 + 373 22 259 717 politia.frontiera@border.gov.md
What has demonstrably changed Date change
28.02.2025 Amended Aviation Liability Insurance; for non-commercial aircraft up to 2.700 kg 151.880 SDR per passenger.
17.04.2025 CT-LPULM Edition 01; explicit recognition procedure for foreign UL licenses.
16.09.2025 CT-SERA Edition 02 as a current set of rules for the Rules of the Air.
05.10.2025 Substantial amendment Government Decision 870/2020; Flight plan regulation unified/stricter, English explicitly specified in controlled airspace.
2025 Implementation of the 8,33-kHz channel grid in the FIR Chișinău.
Official source: Civil Aviation Authority Republic of Moldova - CT-SERA Edition 02 - https://www.caa.md/sites/def ault/files/users-media/media-13/Cadrul%20Normativ/Cerin%C5%A3e%20tehnice/CT-SERA_ED.02.pdf Official source: Civil Aviation Authority - CT-LPULM Edition 01 - https://caa.md/sites/default/files/users-media/me dia-13/Cadrul%20Normativ/Cerin%C5%A3e%20tehnice/34_CT-LPULM_ro.pdf Official source: CAA Moldova - Important Notice / Changes 2025 - https://www.caa.md/en/important-notice Official source: MOLDATSA - Aeronautical Information Management - https://aim.moldatsa.md/ Official source: MOLDATSA - HomeBriefing - https://homebriefing.moldatsa.md/
Official source: CAA / EUROCONTROL - LSSIP Moldova - https://www.caa.md/sites/default/files/media/documents/2025-07/LSSIP%202024%20Moldova%20final.pdf Official Source: Border Police Republic of Moldova - https://border.gov.md/en/node/584 Official Source: CAA Moldova - Flight Authorization - https://www.caa.md/en/flight-authorization
This country overview serves the structured flight preparation. Prior to each flight, up-to-date AIP/eAIP, AIP SUP, NOTAM, weather, up-to-date aerodrome information and any required regulatory approvals shall be checked.
Official direct links
The AIP, supplements, NOTAM, weather and aerodrome data valid on the day of flight remain authoritative. Links open the respective official source in a new window.
This country guide supports individual flight preparation. It does not replace the AIP, AIP SUP, NOTAM, AUP/UUP, weather and aerodrome information valid on the day of flight.
Systematic reproduction, compilation or redistribution of the complete VFR Guide Europe is prohibited.