FIS
Helsinki ControlSector-based, including 121.300 · 123.775 · 124.200 · 125.225 MHz
VFR Guide Europe
At a glance
Sector-based, including 121.300 · 123.775 · 124.200 · 125.225 MHz
7,000 ft in ENKR TMA Center and West
Exceptions only in suitable reserved airspace
File a complete international FPL
Plan alternative navigation and check current warnings
Schengen, external borders and entry procedures.
Read more →Duty, task, activation and closure.
Read more →Sector-dependent frequencies of Helsinki Control.
Read more →Controlled, uncontrolled and special areas.
Read more →VMC minima, minimum heights and FL195.
Read more →Rules for flights in long twilight and night phases.
Read more →Transition Altitude, QNH and cruising altitudes.
Read more →SSR, 8,33 kHz and transitional rules.
Read more →National requirements for ultralight aircraft.
Read more →PPR, operating hours and local procedures.
Read more →Weather service and lack of VOLMET.
Read more →Operational risks and backup navigation.
Read more →The operational statements of this Finnish chapter have been recast for the status 23.08.2026 using the official Finnish and European sources mentioned in the source chapter. Current AIP status: AIRAC AMDT 004/2026 has been effective since 06.08.2026. AIRAC AMDT 005/2026 has already been released, but will only take effect on 01.10.2026. Before the flight, additionally check current NOTAM and AIP SUP.
Topic
Finland - practical statement
Schengen / EU
Yes/Yes
Flight plan at border crossing
Yes, in principle required
Germany - Finland
Schengen/EU internally in principle no specific Airport of Entry; Flight plan remains necessary
Åland
EU Customs Territory, but outside the EU Tax Territory - observe special customs treatment
airspace
Basic Structure Helsinki FIR: G under FL95, C FL95 - FL660, G above FL660; Local CTR/TMA/CTA/FIZ
Night VFR
Allowed with additional Finnish provisions
Transition Altitude
Basically 5000 ft MSL
8.33kHz
Transitional Finnish regime up to 31.12.2027; Planning for international flight 8,33-kHz-capable equipment
UL
Finnish B2 class: two-seater Land-UL to 600 kg; Check foreign UL/registry/license issue separately
GNSS
2026 continues to experience significant disruption; Do not rely solely on GNSS
VOLMET
Not available
Finland belongs to the EU and the Schengen area. In the case of a real internal Schengen flight, any suitable aerodrome for the first landing or flight may in principle be used. the last take-off shall be used unless customs regulations, military restrictions or local airfield rules are precluded. However, the international border crossing remains subject to flight plan requirements.
The Åland Islands belong to the EU customs territory, but not to the EU tax territory. A landing on Åland must therefore not automatically be treated as a normal intra-Community flight under customs and tax law. Practice: For flights landing on Åland, check in advance the current customs procedures and the status of the specific aerodrome.
For flights from or In countries outside Schengen and/or the EU, additional border and customs procedures apply. Norway and Iceland are Schengen states but not EU members; Customs permits may therefore be required when using non-international aerodromes. For other landing sites, special administrative permits and lead times may apply according to AIP. The state border between Finland and Russia can only be crossed from the air via published ATS routes.
In particular, a flight plan is required in Finland for:
Normal case: submit the flight plan no later than 60 minutes before EOBT. A VFR flight conducted entirely within Helsinki FIR may, under the published rule, be filed up to 30 minutes before EOBT. Flight plans are primarily filed electronically through the official Fintraffic systems. If electronic transmission is not possible, the Flight Planning Centre can be contacted at FPC: +358 29 150 2070.
On take-off or landing at aerodromes without active ATS, the pilot shall: Ensure closure yourself.
Situation
Procedures
Start without active ATS
Activate the flight plan immediately before take-off by telephone
Landing without active ATS
Close flight plan by phone immediately after landing
contact
ACC VFR Control: +358 29 150 2071
For the route flight, HELSINKI ACC / HELSINKI CONTROL is decisive. the frequency is sector-dependent; Therefore, there is no single countrywide “Finland Information” frequency. Currently published Helsinki-ACC frequencies: 121.300 123.775 124.200 125.225 126.100 126.300 127.100 127.425 130.975 132.325 132.675 132.725 134.575 135.525 MHz The actual frequency used is determined by the respective ACC sector, the current aeronautical chart and the ATS instructions. Above FL95 English is used; FL95 and below are available Finnish and English.
Vertical area Helsinki FIR
Basic class
from FL95
FL95 to FL660
above FL660
This FIR basic structure does not replace the local airspace check. CTR, TMA, CTA and FIZ exist around commercial aerodromes; Limits, classes and operating hours result from ENR 2.1 and AD 2.
Military and temporarily reserved areas are operationally relevant in Finland. TSA, TRA and Restricted and Danger Areas can be activated via AUP/UUP. ADIZ is subject to additional flight plan and radio requirements. Check before each flight: eAIP / Map + NOTAM + AUP/UUP + current airspace status. Temporarily activated military areas do not derive from a static country leader.
In principle, the European SERA-VMC minima apply. For low uncontrolled airspace, Finland uses the option provided for in SERA to allow reduced flight visibility up to 1.500 m under appropriate conditions and speeds up to 140 kt IAS.
Area
Flight visibility/cloud distance
from FL100 / 10.000 ft
8 km 1.500 m horizontally / 1.000 ft vertically
under 10.000 ft, above 3.000 ft MSL or 1.000 ft AGL
5 km 1.500 m horizontally / 1.000 ft vertically
Low range class C/D
5 km 1.500 m horizontally / 1.000 ft vertically
Low range class G
in principle 5 km; Cloud-free and ground visibility - observe national SERA facilitation
Special VFR is possible after SERA. After its national addition, Finland also allows Special VFR at night under the applicable conditions.
Night VFR is generally allowed in Finland. In addition to the SERA rules, Finland requires a VFR flight at night - except as required for take-off and landing - to be performed at least 1.000 ft above the highest obstacle within a radius of 8 km. If the night VFR flight leaves the vicinity of the aerodrome, a flight plan is required. In addition, the relevant EASA rating and aircraft equipment requirements apply to SEPs. UL: The fact that night VFR is allowed as a mode of operation in Finland does not automatically mean that every foreign national UL license and every UL is eligible for it. I do not have any reliable information on this. For a specifically planned night flight with a foreign UL, Traficom should confirm in advance in writing that the license, license and equipment are sufficient.
According to SERA, normal VFR flights above FL195 are generally not permitted, unless an explicitly provided exception applies. Finland has for the general national approval procedure under SERA. 5005 (d)( 2 )(ii) no corresponding permit procedure set up. Practice: For the normal VFR flight, treat FL195 as an upper regular limit. This shall be without prejudice to specific cases in reserved airspace.
Transition altitude: Basically 5.000 ft MSL. For the published areas ENKR TMA Center/West there is an exception of 7.000 ft. The transition level is determined by ATS depending on the QNH. For VFR horizontal cruise flights from 5.000 ft MSL or 3.000 ft AGL - whichever is the higher - the VFR magnetic track cruise altitudes apply. Magnetic track
Examples of VFR cruising levels
000°-179°
FL55, FL75, FL95...
180°-359°
FL65, FL85, FL105...
An operational transponder with altitude transmission is required, inter alia, in published TMZ and appropriately designated aerodrome airspace. In addition, there are special requirements in uncontrolled airspace below EFHK TMA LOWER. The current AIP calls mode A/C or mode S with altitude transmission. Whether a particular TMZ is active depends on the respective release and ATS operating time. Practice: Always check the transponder request from ENR 2.1 and the current AD/VAC page of the specific flight.
In particular, two-way radio communication is required for controlled VFR flights in airspace C or D as well as in RMZ and ADIZ. Finland has an approved transitional arrangement for 8,33-kHz channelling. Fintraffic ANS continues to use 25-kHz channel spacings during the transition phase; The Finnish exception runs until 31.12.2027. Cockpit practice: For an international flight with a German SEP or UL, plan 8,33-kHz-capable radio system. The Finnish exception does not automatically apply on the arrival and departure route through other states.
UL are nationally regulated. Therefore, EASA rules for SEP must not be automatically transferred to foreign UL. Special consideration shall be given to aircraft register, airworthiness document, pilot licence, medical and the specific type of operation allowed.
Finland knows the national UL classes B1 and B2. For B2, the following maximum limits shall apply, inter alia:
B2 category
Maximum MTOM
Two-seat land aircraft
600 kg
Two-seater water/amphibious aircraft
650 kg
For B2 there is also a maximum housing speed, i.e. lowest stable flight speed in landing configuration of 45 kt CAS. A historical blanket restriction on 450/472,5 kg therefore does not fully reflect the current Finnish regulation.
The Finnish AIP provides for a non-commercial use without authorisation for certain foreign nationally regulated aircraft, in particular if the following conditions are met:
If the requirements are not met, an approval from Traficom is required. For Flight Permissions, the address flightpermissions@traficom.fi is mentioned in the AIP. German D-M-UL: The Finnish AIP explicitly requires registration in the “aircraft register of an EASA member state”. Whether the specific German register form of a D-M air sports device meets this requirement in any case cannot be deduced beyond doubt from the published Finnish primary sources. I do not have any reliable information on this. Before the flight, written confirmation by Traficom is recommended, indicating the number plate, type, MTOM, registration/licensing office and airworthiness document.
The Finnish regulation PEL M2- 70 requires for the driver of a UL either a Finnish national UL license or a foreign UL license that entitles him to fly in Finland. No blanket automatic recognition of each national foreign SPL can be derived from this. For holders of an EASA-LAPL(A)/PPL(A), the Finnish national scheme provides for specific conditions for UL privileges; among other things, documented UL training is required. Foreign National SPL / Medical: General automatic recognition could not be proven from the published Finnish primary sources. I do not have any reliable information on this. Before the first flight with a national foreign UL license, have Traficom confirm in writing the recognition of the specific license and the medical.
The operator shall ensure that, for each flight, the requirements laid down in Regulation (EC) No. 785/2004 required aviation liability insurance is available. Traficom explicitly mentions liability to third parties and, in the case of multi-seater aircraft, passenger liability.
PPR, operating hours, handling, ATS/AFIS times, FIZ/RMZ/TMZ, fuel, UL usage and local restrictions are aerodrome related data and should not be stipulated as permanently valid country information.
Particularly important: A flight to a FIZ during its operating time requires a flight plan. In the case of ATS-closed places, manual activation or Closure of the flight plan via ACC VFR Control.
The Finnish Meteorological Institute (FMI) is responsible. Official aviation meteorological services include METAR, TAF, SIGMET, weather maps and low-level forecasts for VFR. The Finnish self-briefing takes place via the official aviation weather services. Telephone H2 4 weather advice: + 358 600 9 3808 - paid service.
Automatic observations are made at almost all Finnish airports. Automatic systems can detect certain icing, visual, cloudy and weather phenomena less reliably than human observers. VOLMET: Not available in Finland.
Traficom continues to report regular GNSS jamming and spoofing. The official situation picture describes significant disruptions in aviation, especially in southern and central Finland. GNSS incidents are part of the Finnish Aviation Safety Plan 2026. For VFR:
Temporary airspace changes, military activations and short-term restrictions are operationally relevant in Finland. They are deliberately not laid down as permanent country rules in this guide. Before each flight: eAIP + AIP SUP + NOTAM + AUP/UUP + current airspace status.
The following current issues are particularly relevant for flight preparation: Topic
Current status
FPC
+358 29 150 2070
ACC VFR Control
+358 29 150 2071
Flight plan / digital services
Use current Fintraffic systems
UL weight
B2 landplanes to 600 kg; Water/Amphibian to 650 kg
VOLMET
Not available
8.33kHz
Finnish transitional rule to 31.12.2027
Fintraffic ANS - Finnish eAIP / Current Issues https://www.ais.fi/eaip/ AIP Finland GEN 1.2 - Entry, Transit and Departure of Aircraft https://beta.ais.fi/eaip/002-2026_2026_04_16/eAIP/EF-GEN%201.2-en-GB.html AIP Finland ENR 1.10 - Flight Planning https://www.ais.fi/eaip/06%20AUG%202026_2026_08_06/eAIP/EF-ENR%201.10-en-GB.html AIP Finland ENR 2.1 - FIR / ACC / CTA / FIZ / TMA https://www.ais.fi/eaip/06%20AUG%202026_2026_08_06/eAIP/EF-ENR%202.1-en-GB.html AIP Finland GEN 1.5 - Equipment, Transponder, Radio, 8.33 kHz https://www.ais.fi/eaip/003-2026_2026_06_11/eAIP/EF-GEN%201.5-en-GB.html Traficom - OPS M1-1 Rules of the Air https://www.traficom.fi/sites/default/files/media/regulation/OPS%20M1-1%20Lentos%C3%A4%C3%A4nn%C3 %B6t_2025_final.pdf Traficom - PEL M2-70 UL pilot licensing https://www.traficom.fi/sites/default/files/media/regulation/PEL%20M2-70%20maarays%202022_final.pdf Traficom - AIR M5-10 UL airworthiness and weight classes https://traficom.fi/sites/default/files/media/regulation/AIR%20M5-10%202020%20maarays_final.pdf AIP Finland GEN 3.5 - Meteorological Services https://www.ais.fi/eaip/003-2026_2026_06_11/eAIP/EF-GEN%203.5-en-GB.html
Traficom - GNSS interference situation in Finland https://www.traficom.fi/en/news/interference-affecting-mobile-communications-and-satellite-navigation-servic es-continues-finland EUR-Lex - SERA Regulation (EU) No 923/2012, consolidated https://eur-lex.europa.eu/legal-content/DE/TXT/?uri=CELEX%3A02012R0923-20250501
This country guide supports VFR flight preparation, but does not replace the examination of AIP/eAIP, AIP SUP, NOTAM, AUP/UUP, weather information, AD/VAC and required regulatory approvals valid at the time of flight. SEP: The essential rules described here can be clearly proven by AIP, SERA and Traficom. UL aircraft: For certain foreign nationally regulated aircraft, the Finnish AIP contains a clear approval-free rule. In the case of German D-M-UL, the concrete evaluation of the register form remains to be verified. Foreign UL license / Medical: A blanket automatic recognition of each national foreign SPL cannot be proven from the published primary sources. I do not have any reliable information on this. Confirm these points before the flight with Traficom for the specific aircraft and license.
Official direct links
The AIP, supplements, NOTAM, weather and aerodrome data valid on the day of flight remain authoritative. Links open the respective official source in a new window.
This country guide supports individual flight preparation. It does not replace the AIP, AIP SUP, NOTAM, AUP/UUP, weather and aerodrome information valid on the day of flight.
Systematic reproduction, compilation or redistribution of the complete VFR Guide Europe is prohibited.