FIS
Budapest InformationNORTH 119.350 · WEST 125.500 · EAST 133.000 MHz
VFR Guide Europe
At a glance
NORTH 119.350 · WEST 125.500 · EAST 133.000 MHz
Establish radio contact before crossing the boundary
Throughout Budapest FIR
Normal en-route VFR traffic
Uncontrolled / controlled unless instructed otherwise
Schengen, non-Schengen, border control and suitable airfields.
Read more →Flight plan obligation, task, activation and closure.
Read more →Budapest Information, Sectors and the 10 Minute Rule.
Read more →Classes, TIZ, controlled areas and threshold heights.
Read more →SERA, visibility, cloud distances and minimum altitudes.
Read more →Transition Altitude, QNH and Transition Level.
Read more →Regular height limit and special exceptions.
Read more →Additional requirements for SEP and limitations for UL.
Read more →Equipment obligation and published standard codes.
Read more →8,33-kHz channels and national air-to-air channels.
Read more →Recognition, documentation and entry permit.
Read more →PPR, operation, radio, UL usage and VAC testing.
Read more →AUP, NOTAM and military-used areas.
Read more →HungaroMet, low-level products and weather briefing.
Read more →The most important points compact for preparation.
Read more →The operational statements were updated using official Hungarian sources.
Hungary is part of the Schengen area. According to the Hungarian AIP, a flight exclusively between Schengen states is considered an “internal flight”. The first or last landing required for non-Schengen flights at an airfield with passport control then does not work.
In the case of a flight that is not internal to the Schengen Borders Code, the first landing in Hungary or the last take-off from Hungary must take place at an airfield where the required passport control and, if necessary, customs control is available.
Private flights to or from non-Schengen states must submit a General Declaration with flight plan and passenger data to the Hungarian police before take-off.
Contact details
Email gatutaslista@rri.police.hu
Fax + 36 1 296 8245
If an aerodrome is to be used without a regular border crossing point, a temporary border crossing point may be requested under certain conditions. According to the source text, the lead time is at least 10 days.
Category of aerodromes
International airports Budapest/Liszt Ferenc, Debrecen, Hévíz/Balaton
Commercial Aerodromes with Győr/Pér, Pécs/Pogány, Szeged border crossing
Business Aerodrome with Nyíregyháza border crossing
National/private places Only after prior agreement with the operator
In Budapest FIR, flight plan requirements apply, among other things, to:
Schengen does not mean “no flight plan”. Also a normal cross-border VFR flight e.g. B. Austria - Hungary remains generally scheduled flight schedule required.
According to the source text, a special exception exists for certain VFR-GAT flights over the Slovak-Hungarian border under 4.000 ft AMSL in airspace G. The exception does not apply to night VFR and not to flights to or from a third country as defined in the published regulation.
Flight plans can be submitted via the official NetBriefing system or via ARO/AFIS.
Location telephone
ARO Budapest + 36 1 293 4310
ARO Budapest + 36 1 293 4312
When departing from an aerodrome without AFIS, a flight with a checked flight plan shall report the take-off to the appropriate FIC. FIC is explicitly responsible for the activation and closure of flight plans.
If there is no ATS unit at the destination aerodrome, the arrival report must be submitted as soon as possible after landing - at the current FIC frequency, by telephone to the responsible FIC or via NetBriefing.
FIC telephone
WEST + 36 1 293 4102
EAST + 36 1 293 4103
NORTH + 36 1 293 4104
NORTH-EAST +36 1 293 4133
If no suitable means of communication is available after landing, the source text of the AIP provides for the Arrival Report to be transmitted by radio to FIC immediately before landing.
An unclosed flight plan can trigger unnecessary alerting and SAR measures.
HungaroControl operates Budapest FIC H2 4. The spatial distribution can be found in the current FIS sector map.
Sector Callsign Frequency/channel
NORTH Budapest Information 119.350 MHz
WEST Budapest Information 125.500 MHz
EAST Budapest Information 133.000 MHz
NORTH-EAST Budapest Information 134.855 CH
Languages: English and Hungarian.
VFR flights entering the Budapest FIR must make radio contact with the relevant ATS unit at least 10 minutes before the actual border crossing.
The information to be reported shall be flag/identification, destination, position and cruising altitude or flight level according to the source text.
Without pre-established radio contact, the VFR flight may not fly into the Budapest FIR.
For the entry into controlled Hungarian airspace, two-way radio, valid flight plan, transponder and ATC clearance are mentioned in the source text. The state border shall be crossed via the Entry/Exit Significant Points published in ENR 4.4.1.
For VFR, the 9.500 ft AMSL threshold is particularly important. Uncontrolled airspace G shall in principle extend up to 9.500 ft AMSL; These include various TIZs, coordinated airspaces and aerobatic areas.
Altitude / area Flight plan Radio
under 4.000 ft AMSL, normal G basically no* basically no*
4.000-9.500 ft AMSL for continuous two-way communication
TIZ for continuous two-way communication
* Night VFR and international flights are subject to additional requirements.
The controlled en-route airspace is largely Class C. Individual areas are class D; As an example, the source text mentions the Budapest CTR. For the specific flight, the current VFR card or the respective AD 2 /VAC classification is decisive.
Hungary generally applies SERA with nationally published additions.
For VFR cruising above 3.500 ft AMSL, the VFR cruising levels specified by direction of flight shall be applied in accordance with ENR 1.7.5.
Transition altitude: 10.000 ft for the entire Budapest FIR.
QNH Transition Level
≥ 1013,3 hPa FL110
1013,2-977,2 hPa FL120
≤ 977,1 hPa FL130
Within the Budapest FIR, the QNH of Budapest/Liszt Ferenc is used as Regional QNH. In CTR and TIZ, the respective Local QNH is used.
Normal en-route VFR traffic is prohibited above FL195. VFR between FL195 and FL285 is only possible under special conditions, in particular in an ad-hoc segregated airspace or with the prior approval of the Budapest ATS Centre. Above FL285, VFR is generally not allowed.
For normal cruise flight with SEP or UL, practically applies: FL195 is the regular upper VFR limit.
The Hungarian AIP examined in the source text does not publish an independent national rule with the heading “VFR on top allowed/forbidden”. Decisive are the normal VMC, airspace and altitude rules. In low airspace G, earth vision is explicitly required; At night, there are additional requirements for continuous earth vision.
A blanket statement “VFR on top is always allowed in Hungary” is therefore not made.
Night VFR is basically possible. When leaving the vicinity of an aerodrome, the source text indicates in particular:
For foreign UL/sports aircraft, according to the recognition rule cited in the source text: VFR only by day.
According to the source text, a functional SSR transponder is required, among other things, for international VFR flights, VFR in controlled airspace, night VFR, motor-driven VFR traffic in airspace G between 4.000 and 9.500 ft AMSL and VFR in TIZ.
Transport code
Aircraft in uncontrolled airspace 7000
Helicopter 7001
Sailplane 7002
Lighter-than-air aircraft 7003
Controlled airspace 2000, unless another ATC statement
Where radio is required, Hungary requires a 8,33-kHz-capable radio. For international VFR flights, contact is additionally valid at least 10 minutes before FIR border crossing.
For flights in airspace G outside TIZ and under 9.500 ft, the source text publishes four National Light Aviation sections:
Channel division
NLA 1 133.415 CH
NLA 2 135.710 CH
NLA 3 129.985 CH
NLA 4 123.210 CH
The geographical boundaries are shown in the current AIP map. These channels do not replace a mandatory contact with FIC/ATS.
The underlying country text assigns the regulation for foreign sports aircraft to the AIP GEN 1.2 § 3.1.1.2. It explicitly includes, among other things, LSA, Microlights, Autogyros, Homebuilts and light sailplanes.
For a foreign UL that is fully covered by this regulation, the source text does not mention an additional individual prior entry permit.
This shall be distinguished from other foreign aircraft with a non-standardised or Limited Airworthiness Certificate; These may require a prior CAA permit.
In the GEN- 1.2 rule for foreign microlights checked in the source text, no explicit limit of 472,5 kg or 600 kg is mentioned. The regulation is based on status, technical documents, registration, insurance and pilot rating.
Hungarian Civil Aviation Authority
Email caa@ekm.gov.hu
Telephone + 36 1 273 5525 / + 36 1 373 1432
In addition to the airfields fully published in the AIP, Hungary has an official VFR Manual. For smaller places practically applies: make contact with the aerodrome before departure.
Check current before each flight:
These data should not be transferred to the country text as permanently valid individual data, but should be currently taken from the AD page or VFR manual.
Hungary has numerous militarily or time-dependently activated areas. For VFR, the Airspace Use Plan (AUP) alongside AIP and NOTAM is therefore particularly important.
Check AUP + NOTAM before each flight. The AUP does not replace the NOTAM test.
Official service is HungaroMet - Unit of Aviation Meteorology.
Contact details
Web aviation.met.hu
Telephone + 36 1 346 4600 / + 36 1 346 4655
Email rvo@met.hu
Among other things, METAR/SPECI, TAF, SIGMET, Low-Level Significant Weather, wind/temperature maps and other GA weather information are provided. For VFR, low-level products up to FL100 are available.
HUNGARY - RECOGNITION
The following current check points are particularly relevant for flight preparation.
Check point Current status
Budapest Information NORTH-EAST: 134.855 CH; shown in the source text as a change since 134.850 MHz 27.11.2025
Further statements shall be examined in the light of effective official publications.
The following official sources have been cited as the main basis in the underlying country text. For the real flight preparation, the currently valid version shall be used.
Hungarian AIP / eAIP - HungaroControl
HungaroControl VFR Manual
HungaroControl NetBriefing
Airspace Use Plan
HungaroMet Aviation Weather
Safety note: This overview is used for flight preparation, but does not replace current AIP, AIP SUP, NOTAM, weather briefing, current aerodrome information and required regulatory approvals.
Official direct links
The AIP, supplements, NOTAM, weather and aerodrome data valid on the day of flight remain authoritative. Links open the respective official source in a new window.
This country guide supports individual flight preparation. It does not replace the AIP, AIP SUP, NOTAM, AUP/UUP, weather and aerodrome information valid on the day of flight.
Systematic reproduction, compilation or redistribution of the complete VFR Guide Europe is prohibited.