VFR Guide Europe

VFR Guide
Hungary

Research date: 21.08.2026Hungarian AIP · AIRAC AMDT 005/2026 · effective 11 JUN 2026Information for flights under visual flight rules (VFR) in Hungary.

At a glance

Cockpit brief – Hungary

FIS

Budapest Information

NORTH 119.350 · WEST 125.500 · EAST 133.000 MHz

FIR entry

10 minutes beforehand

Establish radio contact before crossing the boundary

Transition altitude

10,000 ft

Throughout Budapest FIR

VFR ceiling

FL195

Normal en-route VFR traffic

SSR code

7000 / 2000

Uncontrolled / controlled unless instructed otherwise

01

Entry

Schengen, non-Schengen, border control and suitable airfields.

Read more →
02

Flight plan

Flight plan obligation, task, activation and closure.

Read more →
03

FIS & FIR approach

Budapest Information, Sectors and the 10 Minute Rule.

Read more →
04

Airspace

Classes, TIZ, controlled areas and threshold heights.

Read more →
05

VFR minimums

SERA, visibility, cloud distances and minimum altitudes.

Read more →
06

altimeters

Transition Altitude, QNH and Transition Level.

Read more →
07

VFR upper limit

Regular height limit and special exceptions.

Read more →
08

Night VFR

Additional requirements for SEP and limitations for UL.

Read more →
09

Transponder

Equipment obligation and published standard codes.

Read more →
10

radio

8,33-kHz channels and national air-to-air channels.

Read more →
11

UL Rules

Recognition, documentation and entry permit.

Read more →
12

Airfields

PPR, operation, radio, UL usage and VAC testing.

Read more →
13

Temporary airspace

AUP, NOTAM and military-used areas.

Read more →
14

Aviation weather

HungaroMet, low-level products and weather briefing.

Read more →
15

Cockpit watch list

The most important points compact for preparation.

Read more →

Basis and topicality

The operational statements were updated using official Hungarian sources.

Entry requirements

Entry from Schengen countries

Hungary is part of the Schengen area. According to the Hungarian AIP, a flight exclusively between Schengen states is considered an “internal flight”. The first or last landing required for non-Schengen flights at an airfield with passport control then does not work.

  • In principle, there is no passport control solely due to the Schengen border crossing.
  • The international VFR flight remains scheduled.
  • The intended aerodrome shall be usable for the specific flight.
  • For smaller national aerodromes, the use shall be coordinated in advance with the operator.

Entry from non-Schengen countries

In the case of a flight that is not internal to the Schengen Borders Code, the first landing in Hungary or the last take-off from Hungary must take place at an airfield where the required passport control and, if necessary, customs control is available.

Private flights to or from non-Schengen states must submit a General Declaration with flight plan and passenger data to the Hungarian police before take-off.

Contact details

Email gatutaslista@rri.police.hu

Fax + 36 1 296 8245

If an aerodrome is to be used without a regular border crossing point, a temporary border crossing point may be requested under certain conditions. According to the source text, the lead time is at least 10 days.

International Aerodromes

Category of aerodromes

International airports Budapest/Liszt Ferenc, Debrecen, Hévíz/Balaton

Commercial Aerodromes with Győr/Pér, Pécs/Pogány, Szeged border crossing

Business Aerodrome with Nyíregyháza border crossing

National/private places Only after prior agreement with the operator

Flight plan

When is a VFR flight plan required?

In Budapest FIR, flight plan requirements apply, among other things, to:

  • all international flights, unless an explicitly published exception applies;
  • any flight in controlled airspace;
  • motor-driven flights in uncontrolled airspace between 4.000 ft AMSL and 9.500 ft AMSL;
  • flights to, from or through a TIZ, except for certain non-motor-powered aircraft;
  • night VFR;
  • VFR above FL195 under the special conditions permitted for this purpose.

Schengen does not mean “no flight plan”. Also a normal cross-border VFR flight e.g. B. Austria - Hungary remains generally scheduled flight schedule required.

According to the source text, a special exception exists for certain VFR-GAT flights over the Slovak-Hungarian border under 4.000 ft AMSL in airspace G. The exception does not apply to night VFR and not to flights to or from a third country as defined in the published regulation.

Flight plan task

Flight plans can be submitted via the official NetBriefing system or via ARO/AFIS.

Location telephone

ARO Budapest + 36 1 293 4310

ARO Budapest + 36 1 293 4312

  • Normally at the latest 60 minutes before EOBT.
  • At the earliest 24 hours before EOBT without DOF requirement.
  • Maximum 5 days in advance.
  • If more than 24 hours lead time must be specified DOF.

Activate and close flight plan

When departing from an aerodrome without AFIS, a flight with a checked flight plan shall report the take-off to the appropriate FIC. FIC is explicitly responsible for the activation and closure of flight plans.

After landing without ATS

If there is no ATS unit at the destination aerodrome, the arrival report must be submitted as soon as possible after landing - at the current FIC frequency, by telephone to the responsible FIC or via NetBriefing.

FIC telephone

WEST + 36 1 293 4102

EAST + 36 1 293 4103

NORTH + 36 1 293 4104

NORTH-EAST +36 1 293 4133

If no suitable means of communication is available after landing, the source text of the AIP provides for the Arrival Report to be transmitted by radio to FIC immediately before landing.

An unclosed flight plan can trigger unnecessary alerting and SAR measures.

Flight Information Service - FIS

HungaroControl operates Budapest FIC H2 4. The spatial distribution can be found in the current FIS sector map.

Sector Callsign Frequency/channel

NORTH Budapest Information 119.350 MHz

WEST Budapest Information 125.500 MHz

EAST Budapest Information 133.000 MHz

NORTH-EAST Budapest Information 134.855 CH

Languages: English and Hungarian.

Entrance to Budapest FIR - very important

VFR flights entering the Budapest FIR must make radio contact with the relevant ATS unit at least 10 minutes before the actual border crossing.

The information to be reported shall be flag/identification, destination, position and cruising altitude or flight level according to the source text.

Without pre-established radio contact, the VFR flight may not fly into the Budapest FIR.

For the entry into controlled Hungarian airspace, two-way radio, valid flight plan, transponder and ATC clearance are mentioned in the source text. The state border shall be crossed via the Entry/Exit Significant Points published in ENR 4.4.1.

Airspace structure

Airspace G

For VFR, the 9.500 ft AMSL threshold is particularly important. Uncontrolled airspace G shall in principle extend up to 9.500 ft AMSL; These include various TIZs, coordinated airspaces and aerobatic areas.

Altitude / area Flight plan Radio

under 4.000 ft AMSL, normal G basically no* basically no*

4.000-9.500 ft AMSL for continuous two-way communication

TIZ for continuous two-way communication

* Night VFR and international flights are subject to additional requirements.

Controlled airspace

The controlled en-route airspace is largely Class C. Individual areas are class D; As an example, the source text mentions the Budapest CTR. For the specific flight, the current VFR card or the respective AD 2 /VAC classification is decisive.

Visual flight rules

Hungary generally applies SERA with nationally published additions.

VMC minimums

  • Under 10.000 ft: 5 km flight visibility.
  • Cloud separation: 1.500 m horizontally / 1.000 ft vertically.
  • In low airspace G - up to 3.000 ft AMSL or 1.000 ft above ground, whichever is higher - basically 5 km, free of clouds and earth vision.
  • Under the conditions provided for in SERA, flight visibility may be reduced to 1.500 m for suitable slow aircraft.

Minimum flight altitudes

  • Over densely populated areas and population gatherings at least 1.000 ft above the highest obstacle within 600 m.
  • Otherwise at least 500 ft above ground/water or above the highest obstacle within 150 m.

Cruising altitudes

For VFR cruising above 3.500 ft AMSL, the VFR cruising levels specified by direction of flight shall be applied in accordance with ENR 1.7.5.

Altimeter setting

Transition altitude: 10.000 ft for the entire Budapest FIR.

QNH Transition Level

≥ 1013,3 hPa FL110

1013,2-977,2 hPa FL120

≤ 977,1 hPa FL130

Within the Budapest FIR, the QNH of Budapest/Liszt Ferenc is used as Regional QNH. In CTR and TIZ, the respective Local QNH is used.

Maximum VFR flight altitude

Normal en-route VFR traffic is prohibited above FL195. VFR between FL195 and FL285 is only possible under special conditions, in particular in an ad-hoc segregated airspace or with the prior approval of the Budapest ATS Centre. Above FL285, VFR is generally not allowed.

For normal cruise flight with SEP or UL, practically applies: FL195 is the regular upper VFR limit.

VFR on top / over clouds

The Hungarian AIP examined in the source text does not publish an independent national rule with the heading “VFR on top allowed/forbidden”. Decisive are the normal VMC, airspace and altitude rules. In low airspace G, earth vision is explicitly required; At night, there are additional requirements for continuous earth vision.

A blanket statement “VFR on top is always allowed in Hungary” is therefore not made.

Night VFR

SEP

Night VFR is basically possible. When leaving the vicinity of an aerodrome, the source text indicates in particular:

  • flight plan required;
  • two-way communication on the appropriate ATS frequency, where available;
  • Cloud base at least 1,500 ft;
  • no normal reduction in flight visibility to 1.500 m;
  • continuous view of the earth in the lower altitude ranges;
  • Area Minimum Altitudes of the ICAO card must not be undershot - except for take-off/landing.

UL

For foreign UL/sports aircraft, according to the recognition rule cited in the source text: VFR only by day.

Transponder

According to the source text, a functional SSR transponder is required, among other things, for international VFR flights, VFR in controlled airspace, night VFR, motor-driven VFR traffic in airspace G between 4.000 and 9.500 ft AMSL and VFR in TIZ.

Standard codes

Transport code

Aircraft in uncontrolled airspace 7000

Helicopter 7001

Sailplane 7002

Lighter-than-air aircraft 7003

Controlled airspace 2000, unless another ATC statement

radio

Where radio is required, Hungary requires a 8,33-kHz-capable radio. For international VFR flights, contact is additionally valid at least 10 minutes before FIR border crossing.

National air-to-air channels

For flights in airspace G outside TIZ and under 9.500 ft, the source text publishes four National Light Aviation sections:

Channel division

NLA 1 133.415 CH

NLA 2 135.710 CH

NLA 3 129.985 CH

NLA 4 123.210 CH

The geographical boundaries are shown in the current AIP map. These channels do not replace a mandatory contact with FIC/ATS.

UL special regulations

The underlying country text assigns the regulation for foreign sports aircraft to the AIP GEN 1.2 § 3.1.1.2. It explicitly includes, among other things, LSA, Microlights, Autogyros, Homebuilts and light sailplanes.

Requirements for the aircraft

  • individual mark or identification mark;
  • valid technical document, e.g. B. Certificate of Airworthiness, Permit to Fly or equivalent;
  • valid civil liability insurance covering Hungary;
  • No commercial operation.

Requirements for the pilot

  • valid licence or equivalent document of the country of registration/identification;
  • valid medical, if this is not part of the license;
  • only VFR by day and within technical operational limits.

Entry permit

For a foreign UL that is fully covered by this regulation, the source text does not mention an additional individual prior entry permit.

This shall be distinguished from other foreign aircraft with a non-standardised or Limited Airworthiness Certificate; These may require a prior CAA permit.

472.5kg / 600kg

In the GEN- 1.2 rule for foreign microlights checked in the source text, no explicit limit of 472,5 kg or 600 kg is mentioned. The regulation is based on status, technical documents, registration, insurance and pilot rating.

Hungarian Civil Aviation Authority

Email caa@ekm.gov.hu

Telephone + 36 1 273 5525 / + 36 1 373 1432

Airfields

In addition to the airfields fully published in the AIP, Hungary has an official VFR Manual. For smaller places practically applies: make contact with the aerodrome before departure.

Check current before each flight:

  • PPR or prior notification;
  • hours of operation;
  • AFIS/uncontrolled operation;
  • current frequency or 8,33-kHz channel;
  • railway condition;
  • refuelling facilities;
  • Possibility to use UL;
  • border/customs status;
  • VAC and NOTAM.

These data should not be transferred to the country text as permanently valid individual data, but should be currently taken from the AD page or VFR manual.

Military and temporarily activated airspace

Hungary has numerous militarily or time-dependently activated areas. For VFR, the Airspace Use Plan (AUP) alongside AIP and NOTAM is therefore particularly important.

  • TRA
  • Danger Areas
  • Restricted areas
  • Military control areas
  • Temporary reserved airspace

Check AUP + NOTAM before each flight. The AUP does not replace the NOTAM test.

Aviation weather

Official service is HungaroMet - Unit of Aviation Meteorology.

Contact details

Web aviation.met.hu

Telephone + 36 1 346 4600 / + 36 1 346 4655

Email rvo@met.hu

Among other things, METAR/SPECI, TAF, SIGMET, Low-Level Significant Weather, wind/temperature maps and other GA weather information are provided. For VFR, low-level products up to FL100 are available.

Cockpit watch list

HUNGARY - RECOGNITION

  1. International VFR flight -> flight schedule.
  2. Make radio contact at least 10 minutes before Budapest-FIR border.
  3. Without this contact, no flight to the Budapest FIR.
  4. International VFR -> Transponder obligation.
  5. Airspace G 4.000-9.500 ft AMSL -> with motor-driven VFR FPL + radio.
  6. TIZ -> basically FPL + radio for motor-driven VFR.
  7. Transition Altitude 10.000 ft
  8. En-route VFR regular maximum FL195.
  9. FIC NORTH-EAST 134.855 CH - 134.850 MHz is obsolete.
  10. Foreign UL/sport aircraft are in principle certified in accordance with GEN 1.2 under the conditions specified therein; for this recognition, VFR applies only by day.
  11. AUP + NOTAM must be checked for military/temporary airspace.

Current test points 2026

The following current check points are particularly relevant for flight preparation.

Check point Current status

Budapest Information NORTH-EAST: 134.855 CH; shown in the source text as a change since 134.850 MHz 27.11.2025

Further statements shall be examined in the light of effective official publications.

Official sources

The following official sources have been cited as the main basis in the underlying country text. For the real flight preparation, the currently valid version shall be used.

  • Hungarian AIP / eAIP: GEN 1.1, GEN 1.2, GEN 3.3, GEN 3.5, ENR 1.1, ENR 1.2, ENR 1.4, ENR 1.7, ENR 1.8, ENR 1.10, ENR 2.1, AD 1.4.
  • HungaroControl VFR Manual - official VFR documents and maps.
  • HungaroControl NetBriefing - flight plan/briefing.
  • Airspace Use Plan (AUP) - current airspace use.
  • HungaroMet Aviation Weather - official flight weather.

Hungarian AIP / eAIP - HungaroControl

HungaroControl VFR Manual

HungaroControl NetBriefing

Airspace Use Plan

HungaroMet Aviation Weather

Safety note: This overview is used for flight preparation, but does not replace current AIP, AIP SUP, NOTAM, weather briefing, current aerodrome information and required regulatory approvals.

Important notice:

This country guide supports individual flight preparation. It does not replace the AIP, AIP SUP, NOTAM, AUP/UUP, weather and aerodrome information valid on the day of flight.

Systematic reproduction, compilation or redistribution of the complete VFR Guide Europe is prohibited.