FIS
Riga Information120.225 MHz · Liepāja FIS/AFIS includes 129.400 MHz
VFR Guide Europe
At a glance
120.225 MHz · Liepāja FIS/AFIS includes 129.400 MHz
Throughout Riga FIR
Practical ceiling for normal VFR cruise
Normally for cross-border VFR
Additional FPL requirement to FL095 near Belarus and Russia
Schengen, External Border, Customs, SEP and UL.
Read more →Duty, task, activation and closure.
Read more →Riga Information and Liepāja FIS/AFIS.
Read more →Class C and G and local CTR/TMA/FIZ/RMZ/TMZ.
Read more →Minimum Heights and FL195.
Read more →SERA rules and open UL recognition.
Read more →Transition altitude and VFR cruising altitudes.
Read more →TMZ, codes, 8,33 kHz and emergency frequency.
Read more →600 kg, Airworthiness and License Recognition.
Read more →PPR, ATS/AFIS, UL approval and border clearance.
Read more →Activation status and temporary areas.
Read more →Special rules for Belarus and Russia.
Read more →AIS, Weather and Pre-Flight Briefing.
Read more →The operational data were compiled using up-to-date official Latvian and European sources.
Checked publication status in the underlying country text: AIRAC AMDT 005/2026 as well as Non-AIRAC AMDT 002/2026, effective since 09.07.2026. In addition, AIP SUP and NOTAM must be checked route-related.
Official source: AIS Latvia / Latvijas Gaisa Satiksme - eAIP
Latvia is a member of the EU and the Schengen area. For the aviation treatment of border crossings, the Latvian AIP distinguishes in particular between flights within the Schengen area and flights from or to the European Union. by non-Schengen states.
In the case of a flight from another Schengen State to Latvia, the first landing may in principle be made at any airfield suitable for the flight in question. Accordingly, a flight to another Schengen state can also be departed from another suitable airfield.
Border control in principle no
No
Airport of Entry exclusively because of Schengen
VFR flight plan yes
Local PPR, operating time, handling and aerodrome regulations shall remain unaffected.
Official source: AIP Latvia GEN 1.2 - Entry, transit and departure of aircraft
When arriving from a country outside the Schengen area, the first landing at an aerodrome or airport must be made. Heliport with an authorised border crossing point. When excursion to a non-Schengen state, the last start must take place there.
Official source: AIP Latvia GEN 1.2
Schengen and Customs Union are not the same. For flights from Switzerland or Norway, for example, customs formalities may exist despite Schengen membership. Therefore, on flights from or in areas outside the EU customs territory additionally check the current customs regulations and the suitability of the airfield.
A regular certified EASA/ICAO aircraft does not have a special general entry permit, provided that airworthiness, certification, insurance and pilot rating are valid. In principle, Latvian legislation requires a valid airworthiness certificate in accordance with the applicable international or international airworthiness regulations. European regulations.
Official source: Latvian Aviation Law
In the case of ultralight aeroplanes, national rules apply. See in detail chapter 11 ‘UL special schemes’.
A flight plan is generally required for a cross-border flight to Latvia.
SERA requires a flight plan especially before flights over international state borders, unless an exception has been agreed between the states concerned.
In addition, Latvia requires, among other things, a flight plan:
Official source: AIP Latvia ENR 1.10 - Flight planning
According to SERA, the flight plan should in principle be submitted at least 60 minutes before departure, unless a special derogation applies. For ATFM-related flights, longer lead times may be required. A flight plan can be submitted according to the current SERA rules up to 120 hours before EOBT.
Official source: EASA Easy Access Rules - SERA
AIS Latvia provides the official Internet Briefing System (IBS). Among other things, NOTAM, SNOWTAM, meteorological information, pre-flight information and flight plan filing are available there. Electronic flight plan filing requires registration.
ARO Riga H2 4
Telephone + 371 67300642
Backup + 371 67783761
Official source: AIS Latvia GEN 3.1 / Riga ARO
When departing from an aerodrome with ATS, the flight plan shall be activated in the normal ATS procedure.
When departing from an uncontrolled Latvian aerodrome, airfield or heliport, the pilot is responsible for activating the flight plan after take-off and transmitting the actual take-off time to the appropriate ATS unit. This should be done immediately after the start on the appropriate frequency.
Official source: AIP Latvia ENR 1.10
After landing, an Arrival Report / ARR message must generally be issued as quickly as possible, provided that the landing has not already been observed by ATS and thus an automatic termination is guaranteed. When landing at a place without ATS, the pilot must close the flight plan via the fastest available connection.
Official source: EASA SERA - Arrival reports / flight plans
For the majority of the Riga FIR, the published FIS frequency is:
RIGA INFORMATION 120.225 MHz
The FIS structure is divided into several geographical sectors. Depending on the sector and the operating time, other ATS units or ATS units can be used outside of certain FIS operating times. Riga ACC/Riga APP.
For the area Liepāja, among others, LIEPAJA FIS / AFIS - 129.400 MHz is published. Operating hours shall not be considered to be permanently unchangeable; They are influenced by AIP, AIP SUP and NOTAM.
The frequency 120.225 MHz is the relevant FIS frequency of RIGA INFORMATION. The ATIS frequency 120.180 MHz published at Riga Airport must be distinguished from this.
Official source: AIP Latvia ENR 2.1 / AD 2 EVRA
A special feature of Latvia is the relatively simple ICAO class structure. According to the Latvian AIP, classes A, B, D, E and F are not used in Riga FIR. For VFR, therefore, class C and G are essentially relevant.
Uncontrolled airspace. FIS may be provided; within specially designated RMZ or other published areas, additional radio obligations apply.
Large-scale is uncontrolled airspace G up to about FL095, above controlled airspace C. However, local CTR, TMA and other controlled airspaces go much deeper. This simplified representation must therefore not be used for navigation. Current VFR card, AIP ENR 2 and NOTAM are relevant.
Official source: AIP Latvia ENR 1.4 / ENR 2.1
This is based on the SERA-VMC minima.
Altitude flight visibility Cloud spacing
Above 10.000 ft AMSL 8 km 1.500 m horizontally / 1.000 ft vertically
below 10.000 ft and above 3.000 ft AMSL or 1.000 ft AGL
5 km 1,500 m horizontal / 1,000 ft vertical
For low flights in Class G, the corresponding SERA regulations and, where applicable, published national conditions apply.
Over densely populated areas or crowds of people: at least 1.000 ft above the highest obstacle within 600 m around the aircraft.
In other areas: at least 500 ft above ground/water, or above the highest obstacle within 150 m, unless an exception applies.
In principle, VFR flights above FL195 are not provided or required. only possible under the special conditions and authorisations expressly provided for in SERA. For normal cruise flights, therefore, FL195 is the practical upper limit.
Official source: EASA Easy Access Rules - SERA
In principle, night VFR is provided for in Latvia under the SERA night VFR regulations. Additional requirements relate in particular to flight plan, weather conditions, freedom from clouds or Cloud spacing, minimum altitudes, radio communication, pilot rating and aircraft equipment.
For VFR within a CTR at night, Latvia publishes among other things:
If a night VFR flight leaves the immediate vicinity of an aerodrome, a flight plan is required according to SERA.
For the automatic recognition of a foreign national UL rating, including night flying rating, no sufficiently clear current Latvian regulation could be established in the underlying search text. Before a night flight with foreign UL, this must be explicitly clarified with the Latvian CAA.
Official source: AIP Latvia / EASA SERA
For the entire Riga FIR: Transition Altitude 5.000 ft AMSL. The transition level is not constant, but depends on the current QNH.
QNH Transition Level
901-942 hPa FL085
943-959 hPa FL080
960-977 hPa FL075
978-995 hPa FL070
996-1013 hPa FL065
1014-1031 hPa FL060
1032-1050 hPa FL055
from 1051 hPa FL050
Magnetic course 000 °- 179 °: 3.500 / 5.500 / 7.500 / 9.500 ft etc.
Magnetic course 180 °- 359 °: 4.500 / 6.500 / 8.500 / 10.500 ft etc. Above the transition altitude correspondingly as flight levels.
Official source: AIP Latvia ENR 1.7 - Altimeter setting procedures
In controlled airspace and published TMZ, a functional SSR transponder is required. Depending on the equipment and airspace, a transponder with 4.096 codes, mode A/C or mode A/C is required. Mode S as well as automatic pressure altitude transmission.
For certain operating modes, 2000 may be used in accordance with the published SSR procedures. An ATS assignment shall take precedence.
Official source: AIP Latvia GEN 1.5 / EASA SERA SSR procedures
The current AIP requires 8,33-kHz VHF radio equipment and two-way communications suitable for VFR in class C and RMZ.
There are also published contact obligations in uncontrolled airspace. Unless a special exception applies, for example, radio contact must be established in good time:
This means that a pilot should not assume that a flight in Class G can be carried out automatically without radio contact.
121.500 MHz In principle, the Latvian AIP requires listening to 121.500 MHz, unless the pilot is employed on another necessary frequency or is in conflict with operational reasons.
For international flights, English is the practical and published ATS language.
Official source: AIP Latvia GEN 1.5
This point is particularly important for a German pilot with a modern 600-kg -UL. Latvia regulates its national UL ratings, inter alia, on national provisions for aircraft in accordance with Annex I to Regulation (EU) 2018/1139. The Latvian UL category cannot be automatically equated with the German 600-kg -UL regulation.
Official source: Cabinet Regulation No 754 / Latvian rules for recreational pilots
Germany uses the national opt-out rule in accordance with Article 2 paragraph 8 of Regulation (EU) 2018/1139 for certain aircraft. This does not automatically give an aircraft operated under such a national regulation an operating right in any other EASA State. EASA clarifies that the operation of such an aircraft in another Member State may be subject to the consent of that State.
Official source: EASA - Article 2 ( 8 ) opt-out
The Latvian Aviation Act provides that aircraft may be operated with an airworthiness certificate recognised in accordance with ICAO Annex 8. For aircraft not holding such an airworthiness certificate, Latvian law requires, in principle, an appropriate approval from the Civil Aviation Agency of Latvia. Many national UL airworthiness documents are not ICAO annex 8 standard CoA.
Official source: Latvian Aviation Law
A current official Latvian publication, which results in a general blanket entry permit for all foreign UL including German 600-kg -UL, was not found in the underlying research text. Therefore, before the first flight to Latvia, have the CAA Latvia confirm in writing that the specific aircraft and pilot documents are accepted.
It is appropriate to indicate:
The recognition together with the aircraft authorisation should be confirmed in writing by the CAA Latvia.
A classification based solely on weight would not be legally sufficient. Crucial are certification basis, national airworthiness documents, Article- 2 ( 8 ) status and recognition by Latvia. A German 600-kg -UL should therefore not be flown in without prior written Latvian confirmation.
Civil Aviation Agency of Latvia
Biroju iela 10, Lidosta ‘Rīga’, Mārupes novads, LV- 1053, Latvia
Telephone + 371 67830936
Email caa@caa.gov.lv
Official source: CAA Latvia - Contacts
For EASA/SEP flights to, from and via Latvia, the relevant European minimum requirements for aviation insurance in accordance with Regulation (EC) No. 785/2004 Depending on the flight and aircraft, in particular risks to passengers, luggage, cargo and third parties on the ground must be covered. A valid proof of insurance should be carried on board.
In the case of nationally certified ULs, it should additionally be checked whether the Latvian CAA requires a specific proof or confirmation for the permit of entry.
Official source: Regulation (EC) No 785/2004
Before each flight check the current AD page and VAC of the specific place. In particular, they shall:
Operating hours may not be accepted as permanently valid from a general country overview. Smaller Latvian aerodromes in particular may have seasonal or PPR-dependent operating conditions.
Official source: AIP Latvia AD / VAC
Latvia has numerous restricted areas, danger areas, military areas, AMC-managed airspace and temporarily activated restricted areas. Activation times and terms of use can be found in the current AIP ENR 5, AIP SUP and NOTAM.
The importance of current supplements is significant: 2026 have also been set up temporary restricted/danger areas by AIP SUP. Such temporary areas must not be adopted as a permanent country rule in a flight driver.
Before each flight: Check VFR card + AIP SUP + NOTAM together.
Official source: AIP Latvia ENR 5 / AIP SUP
VFR flights towards the Latvian border with Russia and Belarus are subject to specific flight plan and airspace requirements. Outside controlled airspace, a flight plan is required in an area from 15 km / 8 NM to the state border to FL095.
Due to the security situation, short-term NOTAM and airspace restrictions can also be published. These shall not be replaced by printed driver data.
Official source: AIP Latvia ENR 1.10
The official Latvian Internet Briefing System (IBS) provides combined flight-preparation information. This includes MET, NOTAM, SNOWTAM, PIB and flight plan filing.
AIS verbal briefing + 371 67300675
ARO Riga H2 4
Telephone + 371 67300642
Backup + 371 67783761
Official source: AIS Latvia GEN 3.1 / Riga ARO
At the time of research 23.08.2026 AIS Latvia publishes: AIRAC AMDT 005/2026 as well as Non-AIRAC AMDT 002/2026, each effective since 09.07.2026. The next already published change will take effect on the 03.09.2026.
The current Latvian VFR chart 1:500.000 is the 15 th Edition, effective since 14.05.2026. A new edition of the same edition is announced for 03.09.2026. This makes it mandatory, especially for flights from 03.09.2026, to use the then effective AIP/card output.
Official source: AIS Latvia - eAIP / VFR support
The following current check points are particularly relevant for flight preparation.
However, for older Latvian pilots, in particular, the following information should not be transferred unchecked:
Temporary NOTAM are deliberately not incorporated into this overview as a permanent country rule.
AIS Latvia / Latvijas Gaisa Satiksme - eAIP
AIS Latvia - VFR support / Cards
Civil Aviation Agency of Latvia
Latvian Aviation Law
National UL Regulation - Cabinet Regulation No. 754
EASA - Standardised European Rules of the Air / SERA
EASA - Article 2 ( 8 ) opt-out
EU Air Insurance - Regulation (EC) No. 785/2004
Particularly relevant AIP chapters: GEN 1.2, GEN 1.5, GEN 3.1, ENR 1.4, ENR 1.7, ENR 1.10, ENR 2.1, ENR 5.1 ff. as well as AD 2 / VAC of the respective airfield.
This country overview serves the structured VFR flight preparation. It does not replace the checking of the AIP/eAIP, AIP SUP, NOTAM, VFR card, weather information, aerodrome documentation and required regulatory approvals valid at the time of flight.
In the case of a foreign nationally licensed UL - in particular a German 600-kg -UL - the written confirmation of the CAA Latvia before crossing the border should be obtained as part of the flight preparation and carried on board.
Official direct links
The AIP, supplements, NOTAM, weather and aerodrome data valid on the day of flight remain authoritative. Links open the respective official source in a new window.
This country guide supports individual flight preparation. It does not replace the AIP, AIP SUP, NOTAM, AUP/UUP, weather and aerodrome information valid on the day of flight.
Systematic reproduction, compilation or redistribution of the complete VFR Guide Europe is prohibited.