FIS
Four PANSA sectorsWarszawa 119.450 · Gdańsk 127.150 · Poznań 126.300 · Kraków 119.275
VFR Guide Europe
At a glance
Warszawa 119.450 · Gdańsk 127.150 · Poznań 126.300 · Kraków 119.275
ATS or ATIS provides transition level
Exceptions only in suitable activated airspace
Unless another code is assigned
Essential for flexible and military airspace
Schengen, external border, airport of entry and customs.
Read more →Exceptions and mandatory cases for international VFR flights.
Read more →PANSA sectors, frequencies and radio contact.
Read more →Controlled, flexible and military structures.
Read more →VMC minima, minimum altitudes and cruising altitudes.
Read more →Transition altitude and QNH procedures.
Read more →Requirements for SEP and open UL questions.
Read more →SSR codes, 8,33 kHz and air-to-air.
Read more →Permit, license recognition and 600-kg -UL.
Read more →PPR, language, UL approval and operating hours.
Read more →Special rules on the eastern and northeastern border.
Read more →New FIS structure, QNH regions and digital preparation.
Read more →The flight operations statements on Poland were researched using current official Polish and European sources. Valid AIP status: eAIP VFR Poland, AIRAC AMDT VFR 08/26, effective since 06.08.2026. The next output 09/26 will only take effect on the 03.09.2026. Poland publishes its own eAIP VFR. For real flight, AIP SUP, NOTAM and, for flexible or military airspace, the current AUP/UUP data must also be checked.
According to the Polish AIP, for a VFR flight from Germany, the Czech Republic or Slovakia to Poland, for example, it is not only because of the border crossing that it is obligated to choose the first Polish airfield as an international airport of entry. The special Polish rule, according to which international VFR flights must use certain approved aerodromes, explicitly refers to flights to or from a non-Schengen state.
Poland has currently introduced temporary controls at its land borders with Germany and Lithuania. The published EU communication refers to these land borders and does not justify a general airport-of-entry obligation for internal private flights.
International VFR flights from or to a non-Schengen state may only take place via the aerodromes provided for this purpose in the Polish AIP, unless there is a special permit or emergency. As international VFR crossing aerodromes, the AIP mentions, among other things:
In the case of goods movement within the EU, there is in principle no customs declaration as when entering from a third country. For flights from countries outside the EU customs territory, the respective customs regulations and the actual customs clearance of the destination airfield must be checked in advance.
For a regularly licensed SEP, there are no special Polish entry permits for a normal private Schengen VFR flight due to the state border alone.
For ultralight aircraft, additional national rules apply. See in detail section UL Special Schemes.
Poland does not have a general schedule requirement for every cross-border VFR flight. According to ENR 1.10, there is in particular an exception for an international VFR flight in uncontrolled airspace if it crosses a state border that is not an external Schengen border. However, it should be noted that the other participating country may in turn request a flight plan.
A pure VFR flight Germany → Poland, Czech Republic → Poland or Slovakia → Poland can be exempted from the flight plan obligation under Polish regulations for a corresponding flight in uncontrolled airspace. Important: This does not automatically mean that the entire flight can be carried out without a flight plan. In addition, the rules of the State of departure and all airspace flown through shall apply.
With the Integrated Web Briefing – IWB, PANSA provides an official system for flight preparation and flight plan processing. Among other things, flight plans can be processed and NOTAM and airspace information can be retrieved. Contact details
Information
ARO Poland
+48 22 574 71 73
aro@pansa.pl
The submission deadlines specified in an earlier AIP issue were at least 30 minutes for purely uncontrolled VFR flights and regularly 60 minutes for flights with controlled airspace or FIR border crossing. Since PANSA 2026 has published changes to the “Flight Planning” area, the deadlines applicable to the specific flight must be adopted directly from the currently valid ENR 1.10. I do not have any reliable information on this. It is not robustly verified that the previously published deadlines have remained unchanged in every detail by AIRAC 08/26.
The acceptance of a VFR flight plan by the ARO does not mean that a planned route below or up to FL095 has been automatically checked for conflicts with activated TSA, TRA or other flexible airspace elements. The responsibility for this remains with the PIC. Before the flight, AUP/UUP or the current airspace availability data must therefore be checked.
When a flight departs from an aerodrome with ATS, the corresponding departure message is normally transmitted by ATS. In the case of a take-off without ATS, the pilot shall ensure that the actual departure time or the activation of the flight plan is transmitted, for example via ARO or the appropriate FIS unit.
After landing, for a flight with a flight plan, the notification of arrival must be made immediately. If no ATS is available at the destination aerodrome, the arrival may be reported via, inter alia, the ARO or the appropriate FIS unit. ARO Poland: + 48 22 574 71 73 If no landing message is received, the Alerting Service or search and rescue process can be triggered after the expiry of the deadline provided for in the AIP. The last verifiable official AIP text indicates 30 minutes after the expected end of the flight. Cockpit Rule: After landing in an uncontrolled place, never assume that the flight plan was automatically closed.
PANSA has significantly changed the FIS structure to the 16.04.2026. The former structure has been restructured; FIS sector boundaries and altimeter setting regions were also adapted.
Currently, the FIS areas exist: Warszawa, Gdańsk, Poznań and Kraków. The FIS is available 24 hours a day.
FIS
Main frequency
Warszawa Information
119.450 MHz
Gdańsk Information
127.150 MHz
Poznań Information
126.300 MHz
Kraków Information
119.275 MHz
This table explicitly does not replace the current VFR card. PANSA itself points out that the valid sector boundaries and frequencies can be taken from the current VFR card.
A PANSA contact page continues to list “FIS Olsztyn 118.775 MHz”. The current FIS description, on the other hand, explains that the former Olsztyn area has now been integrated into the new Warszawa structure. Therefore, 118.775 MHz should not be used unchecked as the current main Olsztyn frequency. Decisive are eAIP and current VFR card.
In uncontrolled Class G airspace, continuous radio contact with FIS is not generally required. FIS shall provide the service to contacting aircraft. For a foreign VFR pilot, the use of Warszawa/Gdańsk/Poznań/Kraków Information is nevertheless particularly recommended because there are extensive flexible and military airspace structures in Poland.
Poland essentially uses ICAO airspace classes C, D and G for general civil airspace. Uncontrolled airspace class G extends outside controlled or specially designated airspace basically from the ground to FL095. Controlled CTR/TMA/CTA break through this structure. Above FL095, the airspace is basically controlled.
In Poland, the testing of AUP/UUP is particularly important. An airspace that appears to be usable on the map can be temporarily reserved for military or other purposes. The activity should be checked immediately before the flight via the official PANSA services.
In principle, the European SERA-VFR rules apply, supplemented by the Polish AIP.
Area
Flight visibility
Cloud separation
Under FL100, above 3.000 ft AMSL or 1.000 ft AGL
min. 5 km
1.500 m horizontally / 1.000 ft vertically
From FL100
min. 8 km
1.500 m horizontally / 1.000 ft vertically
In low airspace Class G, there are facilitations under the conditions set out in SERA and AIP; “Clear of Cloud and with Surface in Sight” For certain slow flights, further reduced visibility values are possible. These exceptions should not be used as normal cruise planning.
SERA exceptions, for example for take-off/landing or special flights approved by the authorities, remain unaffected.
VFR flights above FL195 are generally not permitted. The AIP has narrow exceptions in specially activated or set up airspace elements. For the normal cruise flight, therefore, FL195 is the VFR upper limit.
Above 3.000 ft above ground/water, the VFR cruising levels according to SERA and magnetic course shall be applied.
Special VFR within a CTR is possible with ATC release. The published conditions include, inter alia:
The detailed values and conditions shall be taken from the current ENR 1.2 or the relevant CTR Regulation before use.
The transition altitude is basically 6.500 ft in Warszawa FIR. The transition level is set depending on the air pressure and announced by ATS or ATIS; Typically, this can be, for example, FL080 or, in the case of low QNH, FL090. The Transition Layer should not be used as cruising altitude. In uncontrolled airspace, Poland also works with regional QNH areas. Its boundaries have been changed to 16.04.2026 together with the FIS structure. Therefore, older QNH maps should not be used. Practice: Request Regional QNH from FIS and use the current VFR card or eAIP.
Night VFR is generally permitted in Poland if the pilot, aircraft and flight meet the corresponding European and national requirements.
Night VFR is possible for SEP, provided in particular that the relevant pilot privileges, required aircraft equipment and operating conditions are met.
Whether and under what conditions a foreign-certified UL is allowed to perform night VFR in Poland depends additionally on its national approval, operating license and pilot rights. I do not have any reliable information on this. Before a planned night flight with a foreign UL, this should be explicitly clarified with the Polish Urząd Lotnictwa Cywilnego – ULC.
In the appropriately designated controlled airspace, the Polish AIP requires an operational transponder with at least mode A/C, unless ATC permits an exemption.
Procedures
Code code
VFR without individually assigned squawk
7000
Emergency
7700
Radio interference
the corresponding ICAO/Polish procedure, or Assigned code
TMZ and special transponder requirements must also be taken from the current VFR card and AIP. A blanket statement, according to which every VFR aircraft throughout Poland must necessarily lead Mode S, cannot be derived from the audited Polish AIP authorities.
The European 8,33-kHz requirements also apply in Poland. Where radio is prescribed or a 8,33-kHz channel allocation is used, the corresponding radio installation must be suitable.
Since the end of 2025, the following 8,33-kHz channels have been published for general European GA-Interpilot communication: Channel
Utilisation
123.065 MHz
General GA interpilot communication
123.135 MHz
General GA interpilot communication
These frequencies do not replace FIS or a prescribed ATS frequency.
For FIS and international ATS traffic, English can be used. However, smaller Polish airfields may not automatically assume that English-language radio service is available at all times. The language specifications of the respective AD-4 page or aerodrome card must be checked before the flight.
This section is particularly important for foreign UL pilots because ULs are regulated nationally in Poland and not all EASA rules for SEP can be adopted.
EU, EEA and Swiss UL The Polish aviation authority ULC publishes an important exception: An aircraft registered in an EU State, Switzerland or an EFTA/EEA State holding a valid airworthiness document issued by the State of Registration, even if it is not an ICAO annex- 8 -Certificate-of-Airworthiness, may be exempt from the Polish temporary permit to fly otherwise required. For example, this is of considerable practical importance for many German-registered ultralight aircraft. But: This exemption concerns the approval of the aircraft. It does not automatically mean that every foreign UL pilot license is recognized for each weight class.
If the above-mentioned exception does not apply, ULC requires the application for a temporary permit to fly in Polish airspace. The request should be submitted no later than 7 days before the expected entry into Polish airspace. Copies of, inter alia:
ULC publishes its own procedure for the recognition/validation of foreign UL pilot qualifications. The currently published procedure explicitly mentions the aircraft category UACP to 495 kg. Among other things, license, medical or corresponding medical proof and flight logbook documents are required. Although Poland has national regulations or opt-out structures for heavier ultralight aircraft up to the 600 kg area, this does not automatically result in the recognition of a foreign 600-kg UL pilot licence. For a foreign 600-kg -UL: I have no reliable information that a foreign national UL pilot certificate for a 600-kg -UL without additional Polish recognition will in any case be automatically recognized. Before the flight, this question should be clarified in writing with ULC. For a written request to ULC, at least the State of Registration, mark, type, MTOW, licensing document, pilot licence and medical or medical certificate should be provided.
For an UL, for which a Polish temporary permit must be applied for, ULC explicitly requires proof of insurance. The journey should therefore in any case be accompanied by a valid insurance confirmation stating that Poland or the relevant European scope is included. I do not have any reliable information on this. A flat-rate own Polish minimum amount of cover especially for all foreign 600-kg -UL could not be reliably derived from the currently audited official sources.
Whether an UL is allowed to use a specific aerodrome must be taken from the respective eAIP-VFR AD 4, aerodrome approval or PPR regulation. Do not assume general admissibility.
Polish VFR airfields are now published in their own eAIP VFR – AD 4. Before each flight, at least the following tests shall be carried out:
For flights in Polish border regions, special attention must be paid to the ADIZ published in ENR. For the published ADIZ along the border with the Russian region of Kaliningrad, the AIP mentions among other things:
For flights to Kaliningrad, Belarus or Ukraine, due to possible security and military changes ENR, AIP SUP and NOTAM must be checked particularly carefully immediately before the flight.
The following current changes are officially demonstrable and particularly relevant for flight preparation:
Poland now publishes separately eAIP IFR, eAIP VFR and MIL eAIP. An older reference only to a uniform “AIP Poland” is organizationally obsolete.
The FIS sector boundaries were changed and the Warszawa/Olsztyn areas were reorganized. Old frequency and sector cards may therefore no longer be used.
The associated QNH/Altimeter regions have also been changed to 16.04.2026.
The channels 123.065 and 123.135 MHz were released at the end of 2025. Older travel guides can inevitably contain an outdated stand here.
With the Integrated Web Briefing, PANSA now offers an official digital system for flight plan, NOTAM and airspace information.
A blanket statement that flight plan filing by fax is definitely no longer allowed in Poland would not be sufficiently substantiated. For practical operations, however, PANSA IWB or direct ARO communication is considerably more appropriate today.
Topic
Poland – a practical statement
Schengen flight
No Airport of Entry solely because of Schengen border crossing
Not Schengen
Only approved international aerodromes or Specific authorisation
Flight plan
Not a flat rate for every Schengen border flight
Schengen external border
Flight plan required
ADIZ
Flight plan + radio observe
FIS
Warszawa, Gdańsk, Poznań, Kraków
FIS in Class G
Radio contact not generally mandatory
Uncontrolled airspace
Basically up to FL095 outside controlled/separate structures
VFR upper limit
Basically FL195
Transition Altitude
6.500 ft
VFR Squawk
7000 when no other code is assigned
Particularly important in Poland
8.33kHz
Required according to European standards
UL EU/EEA/CH
Aircraft may be exempt from temporary Polish permit
Foreign 600-kg -UL
Examination of pilot ratings must be carried out separately
Small airfields
Check PPR, language, UL approval and operating hours individually
The following official sources were used as the main basis in the underlying country text. For the real flight preparation, the currently valid version shall be used. PANSA – AIP Poland / eAIP VFR PANSA – Flight Information Service PANSA – Integrated Web Briefing (IWB)
PANSA – ARO / Important telephone numbers and frequencies ULC – Temporary permit / foreign aircraft ULC – Recognition of foreign UL pilot qualifications EU – Temporary Schengen internal border controls EU – 8,33-kHz regulation
Official direct links
The AIP, supplements, NOTAM, weather and aerodrome data valid on the day of flight remain authoritative. Links open the respective official source in a new window.
This country guide supports individual flight preparation. It does not replace the AIP, AIP SUP, NOTAM, AUP/UUP, weather and aerodrome information valid on the day of flight.
Systematic reproduction, compilation or redistribution of the complete VFR Guide Europe is prohibited.